高次谐波对PMU测量精度影响的评估

M. Loper, Uku Salumae, J. Kilter
{"title":"高次谐波对PMU测量精度影响的评估","authors":"M. Loper, Uku Salumae, J. Kilter","doi":"10.1109/ISGTEurope.2017.8260271","DOIUrl":null,"url":null,"abstract":"This paper presents results of the study made to determine the correlation between the increased level of voltage and current harmonics in the transmission network and corresponding PMU measurement accuracy. This topic is relevant in the context of increasing level of power electronic based connections, e.g. wind and solar power plants, HVDC, etc., and due to the increasing development and use of PMU measurement based applications. For this study, several test cases were developed and assessments based on criteria defined in IEEE C37.118.1-2011 standard were made. In the study, three PMU units from different manufacturers were tested and respective results are presented in the paper. It is shown that in general the influence of higher harmonics to PMU measurement accuracy is modest or nonexistent but care should be taken as the exact characteristics of different PMUs is not always available or known.","PeriodicalId":345050,"journal":{"name":"2017 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Assessment of higher harmonics influence to PMU measurement accuracy\",\"authors\":\"M. Loper, Uku Salumae, J. Kilter\",\"doi\":\"10.1109/ISGTEurope.2017.8260271\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents results of the study made to determine the correlation between the increased level of voltage and current harmonics in the transmission network and corresponding PMU measurement accuracy. This topic is relevant in the context of increasing level of power electronic based connections, e.g. wind and solar power plants, HVDC, etc., and due to the increasing development and use of PMU measurement based applications. For this study, several test cases were developed and assessments based on criteria defined in IEEE C37.118.1-2011 standard were made. In the study, three PMU units from different manufacturers were tested and respective results are presented in the paper. It is shown that in general the influence of higher harmonics to PMU measurement accuracy is modest or nonexistent but care should be taken as the exact characteristics of different PMUs is not always available or known.\",\"PeriodicalId\":345050,\"journal\":{\"name\":\"2017 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGTEurope.2017.8260271\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEurope.2017.8260271","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文介绍了输电网络中电压和电流谐波的增加水平与相应PMU测量精度之间的关系的研究结果。该主题是在基于电力电子连接的水平不断提高的背景下相关的,例如风能和太阳能发电厂,HVDC等,并且由于基于PMU测量的应用的不断发展和使用。在本研究中,开发了几个测试用例,并根据IEEE C37.118.1-2011标准定义的标准进行了评估。本文对不同厂家的三台PMU进行了测试,并给出了各自的结果。结果表明,一般来说,高次谐波对PMU测量精度的影响不大或不存在,但由于不同PMU的确切特性并不总是可用或已知,因此应注意。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of higher harmonics influence to PMU measurement accuracy
This paper presents results of the study made to determine the correlation between the increased level of voltage and current harmonics in the transmission network and corresponding PMU measurement accuracy. This topic is relevant in the context of increasing level of power electronic based connections, e.g. wind and solar power plants, HVDC, etc., and due to the increasing development and use of PMU measurement based applications. For this study, several test cases were developed and assessments based on criteria defined in IEEE C37.118.1-2011 standard were made. In the study, three PMU units from different manufacturers were tested and respective results are presented in the paper. It is shown that in general the influence of higher harmonics to PMU measurement accuracy is modest or nonexistent but care should be taken as the exact characteristics of different PMUs is not always available or known.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信