基于Xilinx系统生成器的软硬件评估联合仿真方法:胶囊内窥镜图像压缩算法的案例研究

Qasim Al-shebani, P. Premaratne, P. Vial, D. McAndrew, Brendan Halloran
{"title":"基于Xilinx系统生成器的软硬件评估联合仿真方法:胶囊内窥镜图像压缩算法的案例研究","authors":"Qasim Al-shebani, P. Premaratne, P. Vial, D. McAndrew, Brendan Halloran","doi":"10.1109/ICSPCS.2018.8631737","DOIUrl":null,"url":null,"abstract":"Testing using the co-simulation method of an algorithm is important to visualize the hardware performance of the algorithm. This study aims to introduce a method for comparing the hardware performance of two different algorithms with a focus on the existing compression system for capsule endoscopy as a case study. The size limitation of capsule endoscopy which constrains the power source and the complexity of the hardware utilization are the main reasons for selecting the capsule endoscopy compression system for this case study. Undertaking a comparison between different algorithms from the existing image compression algorithms in capsule endoscopy can highlight the main testing steps of the co-simulation testing method. To allow a fair comparison, the hardware co-simulation is implemented using the same FPGA device for the methods compared in this study and the results acquired are discussed.","PeriodicalId":179948,"journal":{"name":"2018 12th International Conference on Signal Processing and Communication Systems (ICSPCS)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Co-Simulation Method for Hardware/Software Evaluation Using Xilinx System Generator: A Case Study on Image Compression Algorithms for Capsule Endoscopy\",\"authors\":\"Qasim Al-shebani, P. Premaratne, P. Vial, D. McAndrew, Brendan Halloran\",\"doi\":\"10.1109/ICSPCS.2018.8631737\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Testing using the co-simulation method of an algorithm is important to visualize the hardware performance of the algorithm. This study aims to introduce a method for comparing the hardware performance of two different algorithms with a focus on the existing compression system for capsule endoscopy as a case study. The size limitation of capsule endoscopy which constrains the power source and the complexity of the hardware utilization are the main reasons for selecting the capsule endoscopy compression system for this case study. Undertaking a comparison between different algorithms from the existing image compression algorithms in capsule endoscopy can highlight the main testing steps of the co-simulation testing method. To allow a fair comparison, the hardware co-simulation is implemented using the same FPGA device for the methods compared in this study and the results acquired are discussed.\",\"PeriodicalId\":179948,\"journal\":{\"name\":\"2018 12th International Conference on Signal Processing and Communication Systems (ICSPCS)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 12th International Conference on Signal Processing and Communication Systems (ICSPCS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSPCS.2018.8631737\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 12th International Conference on Signal Processing and Communication Systems (ICSPCS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSPCS.2018.8631737","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

使用联合仿真方法对算法进行测试对于可视化算法的硬件性能非常重要。本研究旨在介绍一种比较两种不同算法的硬件性能的方法,并以现有的胶囊内窥镜压缩系统为例进行研究。胶囊内窥镜的尺寸限制对电源的限制以及硬件使用的复杂性是本案例选择胶囊内窥镜压缩系统的主要原因。将不同算法与胶囊内窥镜中现有的图像压缩算法进行比较,可以突出联合仿真测试方法的主要测试步骤。为了进行公平的比较,使用相同的FPGA器件对本研究中比较的方法进行了硬件联合仿真,并讨论了所获得的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Co-Simulation Method for Hardware/Software Evaluation Using Xilinx System Generator: A Case Study on Image Compression Algorithms for Capsule Endoscopy
Testing using the co-simulation method of an algorithm is important to visualize the hardware performance of the algorithm. This study aims to introduce a method for comparing the hardware performance of two different algorithms with a focus on the existing compression system for capsule endoscopy as a case study. The size limitation of capsule endoscopy which constrains the power source and the complexity of the hardware utilization are the main reasons for selecting the capsule endoscopy compression system for this case study. Undertaking a comparison between different algorithms from the existing image compression algorithms in capsule endoscopy can highlight the main testing steps of the co-simulation testing method. To allow a fair comparison, the hardware co-simulation is implemented using the same FPGA device for the methods compared in this study and the results acquired are discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信