地电层析成像和电方法在污染区域识别策略中的适用性

M. Moraru, A. Tanasie
{"title":"地电层析成像和电方法在污染区域识别策略中的适用性","authors":"M. Moraru, A. Tanasie","doi":"10.1109/ISFEE.2016.7803159","DOIUrl":null,"url":null,"abstract":"In this article, we would like discribing the technique underlying the investigations through computed geoelectric tomography done using the resistivity method. The method is designed to reveal information about those formations or bodies which display anormalies of the electrical conductivity and also has long been used to diferentiate the layers that have different levels of conductivity. Apparently these resistivities are usually functions of some variables which are in accordance with the depth of the investigation. The geological surveillance utilizes a wide variety of techniques, each based on different properties or characteristics of the soil. It is accoustomed for most electrical methods to define a function called the apparent resistivity response [ρa], which can be assessed and estimated from measurements. The giding principle of the method - The data collection is made uniformly throughout the profile,the density being determined by the distance between the electrodes and the type of the chosen device. Through one single stretch of the cable we can perform hundreds of multi-electrode measurements of resistivity, and thereby creating a 2D image of the sub-soil similar to a tomography. The data is then filtered and processed using a specialized software, which, unlike the Vertical Electric Survey method (SEV), performs a 2D inversion of all sections according to the lateral variations of the resistivities'-distribution throughout the length of the profile.","PeriodicalId":240170,"journal":{"name":"2016 International Symposium on Fundamentals of Electrical Engineering (ISFEE)","volume":"328 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Geoelectric Tomography and Electrical Methods, with Applicability in the Strategy for Identifying Contaminated Area\",\"authors\":\"M. Moraru, A. Tanasie\",\"doi\":\"10.1109/ISFEE.2016.7803159\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this article, we would like discribing the technique underlying the investigations through computed geoelectric tomography done using the resistivity method. The method is designed to reveal information about those formations or bodies which display anormalies of the electrical conductivity and also has long been used to diferentiate the layers that have different levels of conductivity. Apparently these resistivities are usually functions of some variables which are in accordance with the depth of the investigation. The geological surveillance utilizes a wide variety of techniques, each based on different properties or characteristics of the soil. It is accoustomed for most electrical methods to define a function called the apparent resistivity response [ρa], which can be assessed and estimated from measurements. The giding principle of the method - The data collection is made uniformly throughout the profile,the density being determined by the distance between the electrodes and the type of the chosen device. Through one single stretch of the cable we can perform hundreds of multi-electrode measurements of resistivity, and thereby creating a 2D image of the sub-soil similar to a tomography. The data is then filtered and processed using a specialized software, which, unlike the Vertical Electric Survey method (SEV), performs a 2D inversion of all sections according to the lateral variations of the resistivities'-distribution throughout the length of the profile.\",\"PeriodicalId\":240170,\"journal\":{\"name\":\"2016 International Symposium on Fundamentals of Electrical Engineering (ISFEE)\",\"volume\":\"328 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 International Symposium on Fundamentals of Electrical Engineering (ISFEE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISFEE.2016.7803159\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 International Symposium on Fundamentals of Electrical Engineering (ISFEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISFEE.2016.7803159","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在本文中,我们将描述利用电阻率法进行计算地电层析成像的研究技术。该方法旨在揭示那些显示电导率异常的地层或体的信息,并且长期以来一直用于区分具有不同电导率水平的层。显然,这些电阻率通常是一些变量的函数,这些变量与研究的深度有关。地质监测利用各种各样的技术,每一种技术都基于土壤的不同性质或特征。大多数电学方法都习惯定义一个称为视电阻率响应的函数[ρa],它可以通过测量来评估和估计。该方法的指导原则-在整个剖面上均匀地收集数据,密度由电极之间的距离和所选设备的类型决定。通过电缆的一段拉伸,我们可以进行数百次多电极电阻率测量,从而创建类似于层析成像的底土二维图像。然后使用专门的软件对数据进行过滤和处理,与垂直电测量方法(SEV)不同,该软件根据整个剖面长度上电阻率分布的横向变化对所有剖面进行二维反演。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Geoelectric Tomography and Electrical Methods, with Applicability in the Strategy for Identifying Contaminated Area
In this article, we would like discribing the technique underlying the investigations through computed geoelectric tomography done using the resistivity method. The method is designed to reveal information about those formations or bodies which display anormalies of the electrical conductivity and also has long been used to diferentiate the layers that have different levels of conductivity. Apparently these resistivities are usually functions of some variables which are in accordance with the depth of the investigation. The geological surveillance utilizes a wide variety of techniques, each based on different properties or characteristics of the soil. It is accoustomed for most electrical methods to define a function called the apparent resistivity response [ρa], which can be assessed and estimated from measurements. The giding principle of the method - The data collection is made uniformly throughout the profile,the density being determined by the distance between the electrodes and the type of the chosen device. Through one single stretch of the cable we can perform hundreds of multi-electrode measurements of resistivity, and thereby creating a 2D image of the sub-soil similar to a tomography. The data is then filtered and processed using a specialized software, which, unlike the Vertical Electric Survey method (SEV), performs a 2D inversion of all sections according to the lateral variations of the resistivities'-distribution throughout the length of the profile.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信