用于EMC预测的自动化电缆耦合分析软件

K.R. Kowzlczyk
{"title":"用于EMC预测的自动化电缆耦合分析软件","authors":"K.R. Kowzlczyk","doi":"10.1109/NSEMC.1989.37195","DOIUrl":null,"url":null,"abstract":"Electromagnetic (EM) coupling between cables containing shielded twisted pairs can cause system degradation, i.e., powerline noise induced onto cables used for communication. Software that uses mathematical models of differential- and common-mode coupling between shielded twisted pairs is described. The differential-mode coupling model is derived from Ampere's law and the Biot-Savart law. The common-mode coupling model is based on the percent imbalance in cable-shield current and inductance due to cable-shield distance from a ground plane. EM data tables and a set of routines using these models were generated using structured query language embedded in Fortran. A novel approach was taken to ensure correct results and reduce user error: the program accesses a large existing knowledge base of cable electrical and physical properties, requiring only cable designators and positions from a user to obtain an interference evaluation.<<ETX>>","PeriodicalId":408694,"journal":{"name":"National Symposium on Electromagnetic Compatibility","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Automated cable coupling analysis software for EMC prediction\",\"authors\":\"K.R. Kowzlczyk\",\"doi\":\"10.1109/NSEMC.1989.37195\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electromagnetic (EM) coupling between cables containing shielded twisted pairs can cause system degradation, i.e., powerline noise induced onto cables used for communication. Software that uses mathematical models of differential- and common-mode coupling between shielded twisted pairs is described. The differential-mode coupling model is derived from Ampere's law and the Biot-Savart law. The common-mode coupling model is based on the percent imbalance in cable-shield current and inductance due to cable-shield distance from a ground plane. EM data tables and a set of routines using these models were generated using structured query language embedded in Fortran. A novel approach was taken to ensure correct results and reduce user error: the program accesses a large existing knowledge base of cable electrical and physical properties, requiring only cable designators and positions from a user to obtain an interference evaluation.<<ETX>>\",\"PeriodicalId\":408694,\"journal\":{\"name\":\"National Symposium on Electromagnetic Compatibility\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-05-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"National Symposium on Electromagnetic Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSEMC.1989.37195\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"National Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSEMC.1989.37195","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

包含屏蔽双绞线的电缆之间的电磁(EM)耦合可能导致系统退化,即电力线噪声诱导到用于通信的电缆。描述了使用屏蔽双绞线之间的差分和共模耦合数学模型的软件。微分模耦合模型由安培定律和比奥-萨瓦定律推导而来。共模耦合模型是基于电缆屏蔽层与地平面的距离引起的电缆屏蔽层电流和电感的百分比不平衡。使用嵌入在Fortran中的结构化查询语言生成了EM数据表和一组使用这些模型的例程。采用了一种新颖的方法来确保正确的结果并减少用户错误:该程序访问大量现有的电缆电气和物理特性知识库,只需要用户提供电缆标识和位置即可获得干扰评估
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Automated cable coupling analysis software for EMC prediction
Electromagnetic (EM) coupling between cables containing shielded twisted pairs can cause system degradation, i.e., powerline noise induced onto cables used for communication. Software that uses mathematical models of differential- and common-mode coupling between shielded twisted pairs is described. The differential-mode coupling model is derived from Ampere's law and the Biot-Savart law. The common-mode coupling model is based on the percent imbalance in cable-shield current and inductance due to cable-shield distance from a ground plane. EM data tables and a set of routines using these models were generated using structured query language embedded in Fortran. A novel approach was taken to ensure correct results and reduce user error: the program accesses a large existing knowledge base of cable electrical and physical properties, requiring only cable designators and positions from a user to obtain an interference evaluation.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信