一种用于无袖带血压变化跟踪的便携式多生理信号同步采集装置

Yumin Li, Zhijun Xiao, Feifei Chen, Chenxi Yang, Zhipeng Cai, Jianqing Li, Chengyu Liu
{"title":"一种用于无袖带血压变化跟踪的便携式多生理信号同步采集装置","authors":"Yumin Li, Zhijun Xiao, Feifei Chen, Chenxi Yang, Zhipeng Cai, Jianqing Li, Chengyu Liu","doi":"10.1109/ICSMD57530.2022.10058406","DOIUrl":null,"url":null,"abstract":"Blood pressure (BP) is a vital physiological parameter of the human body. Currently, BP measurement needs to be portable and comfortable. Thus, cuff-less BP measurement is becoming more and more crucial. This paper proposes a portable multi-physiological signal synchronization acquisition device for cuff-less BP variation tracking. The analog front-end circuit is designed to record in Electrocardiogram (ECG), Photoplethysmogram (PPG), and Phonocardiogram (PCG). The effects of the pre-ejection period (PEP) can be reduced using PPG and PCG signals. After that, an artificially induced BP variation experiment is designed, and data is collected from 10 subjects to confirm the reliability of this device. Three pulse transit time indexes (PTT, PTTD, PTTV) is calculated from the PPG and PCG features. Finally, the Pearson correlation coefficients between the reference BP and three PTTs are calculated. The results show that PTTD had the highest correlation with SBP (−0.869 ± 0.153), and PTT had the highest correlation with DBP (−0.737 ± 0.117). Therefore, this device is feasible for tracking BP variations by a cuff-less method.","PeriodicalId":396735,"journal":{"name":"2022 International Conference on Sensing, Measurement & Data Analytics in the era of Artificial Intelligence (ICSMD)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A portable multi-physiological signal synchronization acquisition device for cuff-less blood pressure variation tracking\",\"authors\":\"Yumin Li, Zhijun Xiao, Feifei Chen, Chenxi Yang, Zhipeng Cai, Jianqing Li, Chengyu Liu\",\"doi\":\"10.1109/ICSMD57530.2022.10058406\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Blood pressure (BP) is a vital physiological parameter of the human body. Currently, BP measurement needs to be portable and comfortable. Thus, cuff-less BP measurement is becoming more and more crucial. This paper proposes a portable multi-physiological signal synchronization acquisition device for cuff-less BP variation tracking. The analog front-end circuit is designed to record in Electrocardiogram (ECG), Photoplethysmogram (PPG), and Phonocardiogram (PCG). The effects of the pre-ejection period (PEP) can be reduced using PPG and PCG signals. After that, an artificially induced BP variation experiment is designed, and data is collected from 10 subjects to confirm the reliability of this device. Three pulse transit time indexes (PTT, PTTD, PTTV) is calculated from the PPG and PCG features. Finally, the Pearson correlation coefficients between the reference BP and three PTTs are calculated. The results show that PTTD had the highest correlation with SBP (−0.869 ± 0.153), and PTT had the highest correlation with DBP (−0.737 ± 0.117). Therefore, this device is feasible for tracking BP variations by a cuff-less method.\",\"PeriodicalId\":396735,\"journal\":{\"name\":\"2022 International Conference on Sensing, Measurement & Data Analytics in the era of Artificial Intelligence (ICSMD)\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 International Conference on Sensing, Measurement & Data Analytics in the era of Artificial Intelligence (ICSMD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSMD57530.2022.10058406\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Conference on Sensing, Measurement & Data Analytics in the era of Artificial Intelligence (ICSMD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSMD57530.2022.10058406","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

血压是人体重要的生理参数。目前,血压测量需要便携和舒适。因此,无袖口BP测量变得越来越重要。提出了一种便携式多生理信号同步采集装置,用于无袖带血压变化跟踪。模拟前端电路被设计用于记录心电图(ECG)、光电容积图(PPG)和心音图(PCG)。利用PPG和PCG信号可以减少预弹射期(PEP)的影响。然后设计人工诱导血压变化实验,收集10名受试者的数据,验证该装置的可靠性。根据脉冲传输时间(PPG)和脉冲传输时间(PCG)的特征计算了三个脉冲传输时间指标(PTT、PTTD、PTTV)。最后,计算参考BP与三个ptt之间的Pearson相关系数。结果显示PTTD与收缩压相关性最高(- 0.869±0.153),PTT与DBP相关性最高(- 0.737±0.117)。因此,该装置可用于无袖口法跟踪BP变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A portable multi-physiological signal synchronization acquisition device for cuff-less blood pressure variation tracking
Blood pressure (BP) is a vital physiological parameter of the human body. Currently, BP measurement needs to be portable and comfortable. Thus, cuff-less BP measurement is becoming more and more crucial. This paper proposes a portable multi-physiological signal synchronization acquisition device for cuff-less BP variation tracking. The analog front-end circuit is designed to record in Electrocardiogram (ECG), Photoplethysmogram (PPG), and Phonocardiogram (PCG). The effects of the pre-ejection period (PEP) can be reduced using PPG and PCG signals. After that, an artificially induced BP variation experiment is designed, and data is collected from 10 subjects to confirm the reliability of this device. Three pulse transit time indexes (PTT, PTTD, PTTV) is calculated from the PPG and PCG features. Finally, the Pearson correlation coefficients between the reference BP and three PTTs are calculated. The results show that PTTD had the highest correlation with SBP (−0.869 ± 0.153), and PTT had the highest correlation with DBP (−0.737 ± 0.117). Therefore, this device is feasible for tracking BP variations by a cuff-less method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信