丙酮PLIF法测量超音速注射流场

Hidemi Takahashi, M. Hirota, Hiroki Oso, G. Masuya
{"title":"丙酮PLIF法测量超音速注射流场","authors":"Hidemi Takahashi, M. Hirota, Hiroki Oso, G. Masuya","doi":"10.2322/JJSASS.55.318","DOIUrl":null,"url":null,"abstract":"Structure of flow field formed by normal sonic injection into a Mach 1.8 air stream was investigated with acetone planar laser induced fluorescence (acetone PLIF). Parametric calculation of fluorescence intensity indicates that it represent molar concentration within ±2.5% error for the present experimental condition. For the special situation of isentropic flow without any mixing, Mach number can be deduced from the fluorescence intensity. Mach number distribution from PLIF data was compared with one obtained from PIV measurement, and showed good agreement. The jet trajectories obtained from images visualized by acetone PLIF and Mie scattering are compared. We find that the acetone PLIF gives reasonable trajectory while the Mie scattering over estimate the jet penetration.","PeriodicalId":144591,"journal":{"name":"Journal of The Japan Society for Aeronautical and Space Sciences","volume":"101 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-02-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Measurement of Supersonic Injection Flowfield Using Acetone PLIF\",\"authors\":\"Hidemi Takahashi, M. Hirota, Hiroki Oso, G. Masuya\",\"doi\":\"10.2322/JJSASS.55.318\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Structure of flow field formed by normal sonic injection into a Mach 1.8 air stream was investigated with acetone planar laser induced fluorescence (acetone PLIF). Parametric calculation of fluorescence intensity indicates that it represent molar concentration within ±2.5% error for the present experimental condition. For the special situation of isentropic flow without any mixing, Mach number can be deduced from the fluorescence intensity. Mach number distribution from PLIF data was compared with one obtained from PIV measurement, and showed good agreement. The jet trajectories obtained from images visualized by acetone PLIF and Mie scattering are compared. We find that the acetone PLIF gives reasonable trajectory while the Mie scattering over estimate the jet penetration.\",\"PeriodicalId\":144591,\"journal\":{\"name\":\"Journal of The Japan Society for Aeronautical and Space Sciences\",\"volume\":\"101 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-02-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of The Japan Society for Aeronautical and Space Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2322/JJSASS.55.318\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Japan Society for Aeronautical and Space Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2322/JJSASS.55.318","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

摘要

利用丙酮平面激光诱导荧光(acetone PLIF)研究了1.8马赫气流中正常声波注入形成的流场结构。荧光强度的参数计算表明,在本实验条件下,其所代表的摩尔浓度误差在±2.5%以内。对于没有混合的等熵流动的特殊情况,可以由荧光强度推导出马赫数。将PLIF实测马赫数分布与PIV实测马赫数分布进行了比较,结果吻合较好。比较了丙酮PLIF和Mie散射成像得到的射流轨迹。我们发现丙酮PLIF给出了合理的轨迹,而Mie散射则高估了射流侵彻。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measurement of Supersonic Injection Flowfield Using Acetone PLIF
Structure of flow field formed by normal sonic injection into a Mach 1.8 air stream was investigated with acetone planar laser induced fluorescence (acetone PLIF). Parametric calculation of fluorescence intensity indicates that it represent molar concentration within ±2.5% error for the present experimental condition. For the special situation of isentropic flow without any mixing, Mach number can be deduced from the fluorescence intensity. Mach number distribution from PLIF data was compared with one obtained from PIV measurement, and showed good agreement. The jet trajectories obtained from images visualized by acetone PLIF and Mie scattering are compared. We find that the acetone PLIF gives reasonable trajectory while the Mie scattering over estimate the jet penetration.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信