H. Filho, G. S. Costa, A. D. M. Santos, D. Oliveira
{"title":"软开关电流馈电双向隔离三相DC-DC变换器","authors":"H. Filho, G. S. Costa, A. D. M. Santos, D. Oliveira","doi":"10.1109/COBEP.2017.8257260","DOIUrl":null,"url":null,"abstract":"A soft switching current fed bidirectional isolated three-phase dc-dc converter based on a voltage source dual-active bridge (DAB) topology is presented in this work. Current fed structures have more flexibility to ensure soft switching for a wide operating range, when compared with voltage source topologies, because the variable duty cycle allows maintain a dc link constant between the primary and secondary sides of the converter. Details and description of the proposed converter are presented. A mathematical analysis is realized regarding the power flow behavior and the switching characteristics of the topology. Simulations results considering a design example rated at 48V/380V, 3.5kW are performed to validate the proposed approach.","PeriodicalId":375493,"journal":{"name":"2017 Brazilian Power Electronics Conference (COBEP)","volume":"141 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"A soft switching current fed bidirectional isolated three-phase DC-DC converter\",\"authors\":\"H. Filho, G. S. Costa, A. D. M. Santos, D. Oliveira\",\"doi\":\"10.1109/COBEP.2017.8257260\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A soft switching current fed bidirectional isolated three-phase dc-dc converter based on a voltage source dual-active bridge (DAB) topology is presented in this work. Current fed structures have more flexibility to ensure soft switching for a wide operating range, when compared with voltage source topologies, because the variable duty cycle allows maintain a dc link constant between the primary and secondary sides of the converter. Details and description of the proposed converter are presented. A mathematical analysis is realized regarding the power flow behavior and the switching characteristics of the topology. Simulations results considering a design example rated at 48V/380V, 3.5kW are performed to validate the proposed approach.\",\"PeriodicalId\":375493,\"journal\":{\"name\":\"2017 Brazilian Power Electronics Conference (COBEP)\",\"volume\":\"141 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 Brazilian Power Electronics Conference (COBEP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/COBEP.2017.8257260\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 Brazilian Power Electronics Conference (COBEP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COBEP.2017.8257260","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A soft switching current fed bidirectional isolated three-phase DC-DC converter
A soft switching current fed bidirectional isolated three-phase dc-dc converter based on a voltage source dual-active bridge (DAB) topology is presented in this work. Current fed structures have more flexibility to ensure soft switching for a wide operating range, when compared with voltage source topologies, because the variable duty cycle allows maintain a dc link constant between the primary and secondary sides of the converter. Details and description of the proposed converter are presented. A mathematical analysis is realized regarding the power flow behavior and the switching characteristics of the topology. Simulations results considering a design example rated at 48V/380V, 3.5kW are performed to validate the proposed approach.