{"title":"采用统一潮流控制器的两区电力系统暂态稳定分析","authors":"Vishwakarma Satyendra","doi":"10.18280/AMA_C.730401","DOIUrl":null,"url":null,"abstract":"Occurrence of a fault in a power system causes transients. To stabilize the system, Power System Stabilizer (PSS) and Automatic Voltage Regulator (AVR) are used. This paper considers a typical Four-machine eleven-bus system forming two areas connected by two parallel lines as a case study for investigating the performance of UPFC in achieving stability. By using a UPFC the oscillation introduced by the faults, the rotor angle and speed deviations can be damped out quickly. In the study the UPFC is connected in one of the lines and the fault is assumed on the other line. The effectiveness of UPFC in suppressing power system oscillation is investigated by analyzing four oscillations in rotor angles and change in speeds that occurred in the three machine system considered in this work. A MATLAB simulation has been carried out to demonstrate the performance of the UPFC in achieving transient stability of the Four-machine eleven-bus two area system.","PeriodicalId":130983,"journal":{"name":"Advances in Modelling and Analysis C","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Transient stability analysis of two area power system using unified power flow controller\",\"authors\":\"Vishwakarma Satyendra\",\"doi\":\"10.18280/AMA_C.730401\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Occurrence of a fault in a power system causes transients. To stabilize the system, Power System Stabilizer (PSS) and Automatic Voltage Regulator (AVR) are used. This paper considers a typical Four-machine eleven-bus system forming two areas connected by two parallel lines as a case study for investigating the performance of UPFC in achieving stability. By using a UPFC the oscillation introduced by the faults, the rotor angle and speed deviations can be damped out quickly. In the study the UPFC is connected in one of the lines and the fault is assumed on the other line. The effectiveness of UPFC in suppressing power system oscillation is investigated by analyzing four oscillations in rotor angles and change in speeds that occurred in the three machine system considered in this work. A MATLAB simulation has been carried out to demonstrate the performance of the UPFC in achieving transient stability of the Four-machine eleven-bus two area system.\",\"PeriodicalId\":130983,\"journal\":{\"name\":\"Advances in Modelling and Analysis C\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Modelling and Analysis C\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18280/AMA_C.730401\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Modelling and Analysis C","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18280/AMA_C.730401","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

电力系统发生故障会引起暂态。为了稳定系统,采用了电力系统稳定器(PSS)和自动电压调节器(AVR)。本文以典型的四机十一总线系统为例,研究UPFC在实现稳定方面的性能。采用UPFC可以快速地消除故障引起的振荡、转子角度和转速偏差。在本研究中,UPFC连接在其中一条线路上,故障假设在另一条线路上。通过分析三机系统中转子角度和转速变化的四种振荡,研究了UPFC抑制电力系统振荡的有效性。通过MATLAB仿真验证了UPFC在实现四机11总线二区系统暂态稳定方面的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Transient stability analysis of two area power system using unified power flow controller
Occurrence of a fault in a power system causes transients. To stabilize the system, Power System Stabilizer (PSS) and Automatic Voltage Regulator (AVR) are used. This paper considers a typical Four-machine eleven-bus system forming two areas connected by two parallel lines as a case study for investigating the performance of UPFC in achieving stability. By using a UPFC the oscillation introduced by the faults, the rotor angle and speed deviations can be damped out quickly. In the study the UPFC is connected in one of the lines and the fault is assumed on the other line. The effectiveness of UPFC in suppressing power system oscillation is investigated by analyzing four oscillations in rotor angles and change in speeds that occurred in the three machine system considered in this work. A MATLAB simulation has been carried out to demonstrate the performance of the UPFC in achieving transient stability of the Four-machine eleven-bus two area system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信