中压开关柜备用绝缘气体

M. Hyrenbach, Sebastian Zache
{"title":"中压开关柜备用绝缘气体","authors":"M. Hyrenbach, Sebastian Zache","doi":"10.1109/PCICEUROPE.2016.7604648","DOIUrl":null,"url":null,"abstract":"Although the contribution of SF6 (sulfur hexafluoride) emissions from gas insulated medium-voltage switchgear to man-made global warming is very small, an eco-efficient insulation gas will contribute to a reduction in the carbon footprint of the electricity grid. Based on fluoroketone molecules an alternative to SF6 gas insulation has been developed for medium-voltage switchgear applications. The alternative fluoroketone/air gas mixture combines good electrical performance with a very low global warming potential GWP <; 1. Compared to the global warming potential of 22.800 from SF6, a reduction of nearly 100% can be achieved using the alternative gas. This paper presents main conclusions of the development of a medium-voltage Gas-Insulated Switchgear (GIS) using the new alternative insulation gas, including a comparison of alternative gas technologies and applying experiences from pilot projects for switchgear applications.","PeriodicalId":361172,"journal":{"name":"2016 Petroleum and Chemical Industry Conference Europe (PCIC Europe)","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"52","resultStr":"{\"title\":\"Alternative insulation gas for medium-voltage switchgear\",\"authors\":\"M. Hyrenbach, Sebastian Zache\",\"doi\":\"10.1109/PCICEUROPE.2016.7604648\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Although the contribution of SF6 (sulfur hexafluoride) emissions from gas insulated medium-voltage switchgear to man-made global warming is very small, an eco-efficient insulation gas will contribute to a reduction in the carbon footprint of the electricity grid. Based on fluoroketone molecules an alternative to SF6 gas insulation has been developed for medium-voltage switchgear applications. The alternative fluoroketone/air gas mixture combines good electrical performance with a very low global warming potential GWP <; 1. Compared to the global warming potential of 22.800 from SF6, a reduction of nearly 100% can be achieved using the alternative gas. This paper presents main conclusions of the development of a medium-voltage Gas-Insulated Switchgear (GIS) using the new alternative insulation gas, including a comparison of alternative gas technologies and applying experiences from pilot projects for switchgear applications.\",\"PeriodicalId\":361172,\"journal\":{\"name\":\"2016 Petroleum and Chemical Industry Conference Europe (PCIC Europe)\",\"volume\":\"53 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-06-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"52\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 Petroleum and Chemical Industry Conference Europe (PCIC Europe)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PCICEUROPE.2016.7604648\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Petroleum and Chemical Industry Conference Europe (PCIC Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCICEUROPE.2016.7604648","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 52

摘要

虽然气体绝缘中压开关柜排放的SF6(六氟化硫)对人为全球变暖的贡献非常小,但生态高效的绝缘气体将有助于减少电网的碳足迹。基于氟酮分子的SF6气体绝缘替代品已开发用于中压开关柜应用。替代氟酮/空气气体混合物具有良好的电气性能和极低的全球变暖潜势GWP <;1. 与SF6的全球变暖潜能值22800相比,使用替代气体可以实现近100%的减排。本文介绍了使用新型替代绝缘气体开发中压气体绝缘开关柜(GIS)的主要结论,包括替代气体技术的比较和开关柜应用试点项目的应用经验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Alternative insulation gas for medium-voltage switchgear
Although the contribution of SF6 (sulfur hexafluoride) emissions from gas insulated medium-voltage switchgear to man-made global warming is very small, an eco-efficient insulation gas will contribute to a reduction in the carbon footprint of the electricity grid. Based on fluoroketone molecules an alternative to SF6 gas insulation has been developed for medium-voltage switchgear applications. The alternative fluoroketone/air gas mixture combines good electrical performance with a very low global warming potential GWP <; 1. Compared to the global warming potential of 22.800 from SF6, a reduction of nearly 100% can be achieved using the alternative gas. This paper presents main conclusions of the development of a medium-voltage Gas-Insulated Switchgear (GIS) using the new alternative insulation gas, including a comparison of alternative gas technologies and applying experiences from pilot projects for switchgear applications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信