W. Li, C. Lancée, A. V. D. van der Steen, E. Gussenhoven, N. Bom
{"title":"用高频血管内超声估计血流速度","authors":"W. Li, C. Lancée, A. V. D. van der Steen, E. Gussenhoven, N. Bom","doi":"10.1109/ULTSYM.1996.584350","DOIUrl":null,"url":null,"abstract":"When a cluster of randomly distributed blood particles moves across the ultrasound beam, the received echo signals decorrelate as a function of time. This phenomenon may be used to estimate the flow velocity by measuring the decorrelation rate from a sequence of blood scattering signals. A computer model based on the impulse response method was used to study the lateral decorrelation properties of an IVUS transducer from the extreme near-field up to the far-field. An RF decorrelation-based method for measuring local blood velocity and quantifying volume flow from cross-sectional RF IVUS data was developed and tested in vitro with a flow phantom and in vivo in pig experiments. Preliminary results of this study indicate that the proposed decorrelation method is able to extract 2D velocity profiles and volumetric flow.","PeriodicalId":278111,"journal":{"name":"1996 IEEE Ultrasonics Symposium. Proceedings","volume":"70 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-11-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Blood velocity estimation with high frequency intravascular ultrasound\",\"authors\":\"W. Li, C. Lancée, A. V. D. van der Steen, E. Gussenhoven, N. Bom\",\"doi\":\"10.1109/ULTSYM.1996.584350\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"When a cluster of randomly distributed blood particles moves across the ultrasound beam, the received echo signals decorrelate as a function of time. This phenomenon may be used to estimate the flow velocity by measuring the decorrelation rate from a sequence of blood scattering signals. A computer model based on the impulse response method was used to study the lateral decorrelation properties of an IVUS transducer from the extreme near-field up to the far-field. An RF decorrelation-based method for measuring local blood velocity and quantifying volume flow from cross-sectional RF IVUS data was developed and tested in vitro with a flow phantom and in vivo in pig experiments. Preliminary results of this study indicate that the proposed decorrelation method is able to extract 2D velocity profiles and volumetric flow.\",\"PeriodicalId\":278111,\"journal\":{\"name\":\"1996 IEEE Ultrasonics Symposium. Proceedings\",\"volume\":\"70 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-11-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1996 IEEE Ultrasonics Symposium. Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.1996.584350\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1996 IEEE Ultrasonics Symposium. Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1996.584350","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Blood velocity estimation with high frequency intravascular ultrasound
When a cluster of randomly distributed blood particles moves across the ultrasound beam, the received echo signals decorrelate as a function of time. This phenomenon may be used to estimate the flow velocity by measuring the decorrelation rate from a sequence of blood scattering signals. A computer model based on the impulse response method was used to study the lateral decorrelation properties of an IVUS transducer from the extreme near-field up to the far-field. An RF decorrelation-based method for measuring local blood velocity and quantifying volume flow from cross-sectional RF IVUS data was developed and tested in vitro with a flow phantom and in vivo in pig experiments. Preliminary results of this study indicate that the proposed decorrelation method is able to extract 2D velocity profiles and volumetric flow.