{"title":"电磁干扰和功能安全为什么传统的免疫测试是不充分的,应该做什么","authors":"K. Armstrong","doi":"10.1109/EMCZUR.2006.214973","DOIUrl":null,"url":null,"abstract":"IEC 61508 is the basic international standard for the functional safety of electrical, electronic and programmable electronic (E/E/PE) equipment. It requires electromagnetic interference (EMI) to be controlled for safety reasons, but does not say how. This paper describes shortcomings in the traditional approach to EMI, and introduces the good EMI practices required for controlling EMI for functional safety","PeriodicalId":130489,"journal":{"name":"2006 17th International Zurich Symposium on Electromagnetic Compatibility","volume":"99 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"EMI and functional safety why traditional immunity testing is inadequate and what should be done instead\",\"authors\":\"K. Armstrong\",\"doi\":\"10.1109/EMCZUR.2006.214973\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"IEC 61508 is the basic international standard for the functional safety of electrical, electronic and programmable electronic (E/E/PE) equipment. It requires electromagnetic interference (EMI) to be controlled for safety reasons, but does not say how. This paper describes shortcomings in the traditional approach to EMI, and introduces the good EMI practices required for controlling EMI for functional safety\",\"PeriodicalId\":130489,\"journal\":{\"name\":\"2006 17th International Zurich Symposium on Electromagnetic Compatibility\",\"volume\":\"99 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-05-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2006 17th International Zurich Symposium on Electromagnetic Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EMCZUR.2006.214973\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 17th International Zurich Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCZUR.2006.214973","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
EMI and functional safety why traditional immunity testing is inadequate and what should be done instead
IEC 61508 is the basic international standard for the functional safety of electrical, electronic and programmable electronic (E/E/PE) equipment. It requires electromagnetic interference (EMI) to be controlled for safety reasons, but does not say how. This paper describes shortcomings in the traditional approach to EMI, and introduces the good EMI practices required for controlling EMI for functional safety