{"title":"使用广域测量系统的电压稳定性监测","authors":"B. Genet, J. Maun","doi":"10.1109/PCT.2007.4538573","DOIUrl":null,"url":null,"abstract":"A new monitoring method based on a wide-area network of Phaser Measurement Units (PMU) is proposed. This tool detects on-line and in real-time an incipient voltage instability in the power system. A geographical visualization is introduced to monitor efficiently the state of the network. The method is general and can be implemented in any part of a network prone to voltage instability. It can be used to trigger corrective actions to avoid a collapse. The hypotheses and the results of the new method will be discussed in regard with those given by the Thevenin's equivalent computed at the load bus.","PeriodicalId":356805,"journal":{"name":"2007 IEEE Lausanne Power Tech","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"29","resultStr":"{\"title\":\"Voltage-Stability Monitoring Using Wide-Area Measurement Systems\",\"authors\":\"B. Genet, J. Maun\",\"doi\":\"10.1109/PCT.2007.4538573\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new monitoring method based on a wide-area network of Phaser Measurement Units (PMU) is proposed. This tool detects on-line and in real-time an incipient voltage instability in the power system. A geographical visualization is introduced to monitor efficiently the state of the network. The method is general and can be implemented in any part of a network prone to voltage instability. It can be used to trigger corrective actions to avoid a collapse. The hypotheses and the results of the new method will be discussed in regard with those given by the Thevenin's equivalent computed at the load bus.\",\"PeriodicalId\":356805,\"journal\":{\"name\":\"2007 IEEE Lausanne Power Tech\",\"volume\":\"52 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"29\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE Lausanne Power Tech\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PCT.2007.4538573\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Lausanne Power Tech","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCT.2007.4538573","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Voltage-Stability Monitoring Using Wide-Area Measurement Systems
A new monitoring method based on a wide-area network of Phaser Measurement Units (PMU) is proposed. This tool detects on-line and in real-time an incipient voltage instability in the power system. A geographical visualization is introduced to monitor efficiently the state of the network. The method is general and can be implemented in any part of a network prone to voltage instability. It can be used to trigger corrective actions to avoid a collapse. The hypotheses and the results of the new method will be discussed in regard with those given by the Thevenin's equivalent computed at the load bus.