非正弦激励下基于介电损耗系数测量的绝缘评定

Pratic A Muntakim, Shubin Zhang, Jun-yan Zhang, B. Phung
{"title":"非正弦激励下基于介电损耗系数测量的绝缘评定","authors":"Pratic A Muntakim, Shubin Zhang, Jun-yan Zhang, B. Phung","doi":"10.1109/catcon52335.2021.9670506","DOIUrl":null,"url":null,"abstract":"Measurement of the dielectric dissipation factor (DDF) is an important technique for assessing the condition of the insulation in high voltage equipment. Traditionally, pure sinusoidal excitation at the power frequency is used in the testing whereas in reality, the grid voltage is often distorted with harmonics. This paper investigates the impact of harmonics on the DDF measurement. A mathematical expression is developed to quantify the effect of the harmonics on the DDF measured value as compared to the case of non-distorted excitation. It is shown that under the same total RMS magnitude of applied voltage, the DDF decreases with increasing harmonic proportion in the excitation waveform. For validation, laboratory experiments as well as computer simulations were carried out from which the data obtained were obtained and compared with the analytical results.","PeriodicalId":162130,"journal":{"name":"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Insulation Assessment Based on Dielectric Dissipation Factor Measurement under Non-sinusoidal Excitation\",\"authors\":\"Pratic A Muntakim, Shubin Zhang, Jun-yan Zhang, B. Phung\",\"doi\":\"10.1109/catcon52335.2021.9670506\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Measurement of the dielectric dissipation factor (DDF) is an important technique for assessing the condition of the insulation in high voltage equipment. Traditionally, pure sinusoidal excitation at the power frequency is used in the testing whereas in reality, the grid voltage is often distorted with harmonics. This paper investigates the impact of harmonics on the DDF measurement. A mathematical expression is developed to quantify the effect of the harmonics on the DDF measured value as compared to the case of non-distorted excitation. It is shown that under the same total RMS magnitude of applied voltage, the DDF decreases with increasing harmonic proportion in the excitation waveform. For validation, laboratory experiments as well as computer simulations were carried out from which the data obtained were obtained and compared with the analytical results.\",\"PeriodicalId\":162130,\"journal\":{\"name\":\"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/catcon52335.2021.9670506\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 5th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/catcon52335.2021.9670506","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

介质耗散系数的测量是评估高压设备绝缘状况的一项重要技术。传统的测试方法是在工频处采用纯正弦激励,而在实际中,电网电压经常受到谐波的畸变。本文研究了谐波对DDF测量的影响。建立了一个数学表达式来量化谐波对DDF测量值的影响,并与无畸变激励的情况进行了比较。结果表明,在施加电压总均方根值相同的情况下,DDF随激励波形中谐波比例的增加而减小。为了验证,进行了实验室实验和计算机模拟,从中获得了数据,并与分析结果进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Insulation Assessment Based on Dielectric Dissipation Factor Measurement under Non-sinusoidal Excitation
Measurement of the dielectric dissipation factor (DDF) is an important technique for assessing the condition of the insulation in high voltage equipment. Traditionally, pure sinusoidal excitation at the power frequency is used in the testing whereas in reality, the grid voltage is often distorted with harmonics. This paper investigates the impact of harmonics on the DDF measurement. A mathematical expression is developed to quantify the effect of the harmonics on the DDF measured value as compared to the case of non-distorted excitation. It is shown that under the same total RMS magnitude of applied voltage, the DDF decreases with increasing harmonic proportion in the excitation waveform. For validation, laboratory experiments as well as computer simulations were carried out from which the data obtained were obtained and compared with the analytical results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信