U. Schwerthoeffer, Christopher Warter, R. Weigel, D. Kissinger
{"title":"用于微流控医学中葡萄糖检测的微带共振生物传感器","authors":"U. Schwerthoeffer, Christopher Warter, R. Weigel, D. Kissinger","doi":"10.1109/BIOWIRELESS.2014.6827728","DOIUrl":null,"url":null,"abstract":"A highly sensitive biosensor to detect small variations of glucose concentrations in water is proposed. The sensor structure is based on a planar half-wavelength (lambda/2) microstrip line (MSL) resonator with a microflu-idic container placed on top. The interaction between the electric field and the milliliter range water-glucose solutions under test can be observed measuring the phase shift of the S-parameter from 3.95 to 4.10 GHz. Combining the microwave detection and the microfluidic network, a time efficient and low cost architecture is presented. With this technique, a very sensitive water-glucose concentration of less than 50 mg/dl can be separated.","PeriodicalId":341652,"journal":{"name":"2014 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"A microstrip resonant biosensor for aqueous glucose detection in microfluidic medical applications\",\"authors\":\"U. Schwerthoeffer, Christopher Warter, R. Weigel, D. Kissinger\",\"doi\":\"10.1109/BIOWIRELESS.2014.6827728\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A highly sensitive biosensor to detect small variations of glucose concentrations in water is proposed. The sensor structure is based on a planar half-wavelength (lambda/2) microstrip line (MSL) resonator with a microflu-idic container placed on top. The interaction between the electric field and the milliliter range water-glucose solutions under test can be observed measuring the phase shift of the S-parameter from 3.95 to 4.10 GHz. Combining the microwave detection and the microfluidic network, a time efficient and low cost architecture is presented. With this technique, a very sensitive water-glucose concentration of less than 50 mg/dl can be separated.\",\"PeriodicalId\":341652,\"journal\":{\"name\":\"2014 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-06-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIOWIRELESS.2014.6827728\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOWIRELESS.2014.6827728","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A microstrip resonant biosensor for aqueous glucose detection in microfluidic medical applications
A highly sensitive biosensor to detect small variations of glucose concentrations in water is proposed. The sensor structure is based on a planar half-wavelength (lambda/2) microstrip line (MSL) resonator with a microflu-idic container placed on top. The interaction between the electric field and the milliliter range water-glucose solutions under test can be observed measuring the phase shift of the S-parameter from 3.95 to 4.10 GHz. Combining the microwave detection and the microfluidic network, a time efficient and low cost architecture is presented. With this technique, a very sensitive water-glucose concentration of less than 50 mg/dl can be separated.