线路避雷器在双回输电线路上的应用

M. Ishii, H. Kawamura
{"title":"线路避雷器在双回输电线路上的应用","authors":"M. Ishii, H. Kawamura","doi":"10.1109/SIPDA.2011.6088437","DOIUrl":null,"url":null,"abstract":"Installation of line surge arresters is quite effective in improving lightning performance of transmission lines. So, cost-effective installation schemes depending on the condition of lines have been sought. In recent years, due to the reduction of the cost of line surge arresters for lower voltage transmission lines, installation rate at some lower voltage transmission lines in Japan has much improved, and failures of line surge arresters have been reported along with it At such transmission lines, failures of surge arresters need to be taken into account in evaluating the lightning performance. The lightning performance of double-circuit transmission lines equipped with three or more arresters per tower taking account of their failures is discussed.","PeriodicalId":277573,"journal":{"name":"2011 International Symposium on Lightning Protection","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Application of line surge arresters to double-circuit transmission lines\",\"authors\":\"M. Ishii, H. Kawamura\",\"doi\":\"10.1109/SIPDA.2011.6088437\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Installation of line surge arresters is quite effective in improving lightning performance of transmission lines. So, cost-effective installation schemes depending on the condition of lines have been sought. In recent years, due to the reduction of the cost of line surge arresters for lower voltage transmission lines, installation rate at some lower voltage transmission lines in Japan has much improved, and failures of line surge arresters have been reported along with it At such transmission lines, failures of surge arresters need to be taken into account in evaluating the lightning performance. The lightning performance of double-circuit transmission lines equipped with three or more arresters per tower taking account of their failures is discussed.\",\"PeriodicalId\":277573,\"journal\":{\"name\":\"2011 International Symposium on Lightning Protection\",\"volume\":\"35 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Symposium on Lightning Protection\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIPDA.2011.6088437\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Symposium on Lightning Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIPDA.2011.6088437","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

线路避雷器的安装对于提高输电线路的防雷性能是非常有效的。因此,根据线路状况寻找具有成本效益的安装方案。近年来,由于低压输电线路线路避雷器成本的降低,日本一些低压输电线路的安装率有了很大的提高,同时也有线路避雷器故障的报道。在这类输电线路中,避雷器的故障是评估防雷性能时需要考虑的因素。讨论了每塔安装三个或三个以上避雷器的双回传输线的防雷性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application of line surge arresters to double-circuit transmission lines
Installation of line surge arresters is quite effective in improving lightning performance of transmission lines. So, cost-effective installation schemes depending on the condition of lines have been sought. In recent years, due to the reduction of the cost of line surge arresters for lower voltage transmission lines, installation rate at some lower voltage transmission lines in Japan has much improved, and failures of line surge arresters have been reported along with it At such transmission lines, failures of surge arresters need to be taken into account in evaluating the lightning performance. The lightning performance of double-circuit transmission lines equipped with three or more arresters per tower taking account of their failures is discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信