{"title":"saw /GC系统中锯传感器频率基线噪声优化","authors":"Minghua Liu, Jiuling Liu, Shitang He","doi":"10.1109/SPAWDA.2014.6998525","DOIUrl":null,"url":null,"abstract":"The GC-SAW system which can rapidly detect volatile organic compounds (VOCs) has been development. The detection limit depends on both response and the baseline noise of frequency in this system. The frequency baseline noise includes the Oscillator noise and temperature coefficient of frequency (TCF) noise. The TCF of the SAW sensor is hard to remove, so the optimization is base on both SAW oscillator and the thermostat in this paper.","PeriodicalId":412736,"journal":{"name":"Proceedings of the 2014 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimization frequency baseline noise of saw sensor in SAW/GC system\",\"authors\":\"Minghua Liu, Jiuling Liu, Shitang He\",\"doi\":\"10.1109/SPAWDA.2014.6998525\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The GC-SAW system which can rapidly detect volatile organic compounds (VOCs) has been development. The detection limit depends on both response and the baseline noise of frequency in this system. The frequency baseline noise includes the Oscillator noise and temperature coefficient of frequency (TCF) noise. The TCF of the SAW sensor is hard to remove, so the optimization is base on both SAW oscillator and the thermostat in this paper.\",\"PeriodicalId\":412736,\"journal\":{\"name\":\"Proceedings of the 2014 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 2014 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SPAWDA.2014.6998525\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2014 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPAWDA.2014.6998525","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Optimization frequency baseline noise of saw sensor in SAW/GC system
The GC-SAW system which can rapidly detect volatile organic compounds (VOCs) has been development. The detection limit depends on both response and the baseline noise of frequency in this system. The frequency baseline noise includes the Oscillator noise and temperature coefficient of frequency (TCF) noise. The TCF of the SAW sensor is hard to remove, so the optimization is base on both SAW oscillator and the thermostat in this paper.