M. S. Bessa, R. S. França, M. Torres
{"title":"用于干涉长度测量的高精度混合直流温度桥的升级","authors":"M. S. Bessa, R. S. França, M. Torres","doi":"10.1109/CPEM.2014.6898298","DOIUrl":null,"url":null,"abstract":"A mix of modern automated, non-invasive minimum-changing approaches was designed to improve temperature measurement speed and metrological reliability for interferometric measurements using good performance old temperature bridge system, which was based on clever combination of hybrid thermocouple plus platinum resistance measurements, good overall electrical stability, and periodic verifications. A Labview application was developed to accurate, continuous and simultaneous time acquisition of voltage signals at different sensors and system points through a multi-channel interfaceable multimeter, maintaining original features. That allows cross validation of both systems with best length calibration uncertainties and calibration practices using fixed points cells as temperature primary references.","PeriodicalId":256575,"journal":{"name":"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Upgrade of high accuracy hybrid DC temperature bridge for interferometric length measurements\",\"authors\":\"M. S. Bessa, R. S. França, M. Torres\",\"doi\":\"10.1109/CPEM.2014.6898298\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A mix of modern automated, non-invasive minimum-changing approaches was designed to improve temperature measurement speed and metrological reliability for interferometric measurements using good performance old temperature bridge system, which was based on clever combination of hybrid thermocouple plus platinum resistance measurements, good overall electrical stability, and periodic verifications. A Labview application was developed to accurate, continuous and simultaneous time acquisition of voltage signals at different sensors and system points through a multi-channel interfaceable multimeter, maintaining original features. That allows cross validation of both systems with best length calibration uncertainties and calibration practices using fixed points cells as temperature primary references.\",\"PeriodicalId\":256575,\"journal\":{\"name\":\"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM.2014.6898298\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"29th Conference on Precision Electromagnetic Measurements (CPEM 2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2014.6898298","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了提高干涉测量的温度测量速度和计量可靠性,设计了一种现代自动化、非侵入性最小变化方法的组合,使用性能良好的旧温度桥系统,该系统基于混合热电偶和铂电阻测量的巧妙组合,具有良好的整体电气稳定性和周期性验证。开发了Labview应用程序,通过多通道可接口万用表对不同传感器和系统点的电压信号进行精确、连续和同时的时间采集,保持原有特征。这样就可以交叉验证两个系统的最佳长度校准不确定性和校准实践,使用定点细胞作为温度主要参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Upgrade of high accuracy hybrid DC temperature bridge for interferometric length measurements
A mix of modern automated, non-invasive minimum-changing approaches was designed to improve temperature measurement speed and metrological reliability for interferometric measurements using good performance old temperature bridge system, which was based on clever combination of hybrid thermocouple plus platinum resistance measurements, good overall electrical stability, and periodic verifications. A Labview application was developed to accurate, continuous and simultaneous time acquisition of voltage signals at different sensors and system points through a multi-channel interfaceable multimeter, maintaining original features. That allows cross validation of both systems with best length calibration uncertainties and calibration practices using fixed points cells as temperature primary references.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信