{"title":"电缆结构对频域反射法故障定位的影响","authors":"Y. Ohki, N. Hirai","doi":"10.1109/CEIDP.2015.7352023","DOIUrl":null,"url":null,"abstract":"The authors have demonstrated that the estimation of the precise locations of points in cables aged thermally or mechanically or by the irradiation of gamma rays is possible by a combination of frequency domain reflectometry (FDR) and inverse fast Fourier transform (IFFT). This paper examines how this ability of fault location depends on the type and structure of the cable, using several kinds of polymer insulated cables such as triple core cables insulated with flame-retardant ethylene propylene diene copolymer (FR-EPDM), dual core cables insulated with silicone rubber (SiR) or crosslinked polyolefin (XLPO), and coaxial cylindrical cables insulated with low density polyethylene (LDPE). As a result, for cables with lengths of 16 to 72 m, the maximum sensitivity is attained when the highest frequency of the inputted electromagnetic waves is 1.0 GHz or higher for coaxial cables, but around 600 to 800 MHz for dual or triple core cables.","PeriodicalId":432404,"journal":{"name":"2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","volume":"323 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Influence of cable structure on the fault location by frequency domain reflectometry\",\"authors\":\"Y. Ohki, N. Hirai\",\"doi\":\"10.1109/CEIDP.2015.7352023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors have demonstrated that the estimation of the precise locations of points in cables aged thermally or mechanically or by the irradiation of gamma rays is possible by a combination of frequency domain reflectometry (FDR) and inverse fast Fourier transform (IFFT). This paper examines how this ability of fault location depends on the type and structure of the cable, using several kinds of polymer insulated cables such as triple core cables insulated with flame-retardant ethylene propylene diene copolymer (FR-EPDM), dual core cables insulated with silicone rubber (SiR) or crosslinked polyolefin (XLPO), and coaxial cylindrical cables insulated with low density polyethylene (LDPE). As a result, for cables with lengths of 16 to 72 m, the maximum sensitivity is attained when the highest frequency of the inputted electromagnetic waves is 1.0 GHz or higher for coaxial cables, but around 600 to 800 MHz for dual or triple core cables.\",\"PeriodicalId\":432404,\"journal\":{\"name\":\"2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)\",\"volume\":\"323 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2015.7352023\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2015.7352023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

作者已经证明,通过频域反射法(FDR)和快速反傅立叶变换(IFFT)的结合,可以对热老化、机械老化或伽玛射线照射的电缆中点的精确位置进行估计。本文研究了这种故障定位能力如何取决于电缆的类型和结构,使用几种聚合物绝缘电缆,如用阻燃乙丙二烯共聚物(FR-EPDM)绝缘的三芯电缆,用硅橡胶(SiR)或交联聚烯烃(XLPO)绝缘的双芯电缆,以及用低密度聚乙烯(LDPE)绝缘的同轴圆柱形电缆。因此,对于长度为16 ~ 72m的电缆,同轴电缆输入电磁波的最高频率为1.0 GHz及以上时灵敏度最高,双芯或三芯电缆输入电磁波的最高频率为600 ~ 800mhz时灵敏度最高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of cable structure on the fault location by frequency domain reflectometry
The authors have demonstrated that the estimation of the precise locations of points in cables aged thermally or mechanically or by the irradiation of gamma rays is possible by a combination of frequency domain reflectometry (FDR) and inverse fast Fourier transform (IFFT). This paper examines how this ability of fault location depends on the type and structure of the cable, using several kinds of polymer insulated cables such as triple core cables insulated with flame-retardant ethylene propylene diene copolymer (FR-EPDM), dual core cables insulated with silicone rubber (SiR) or crosslinked polyolefin (XLPO), and coaxial cylindrical cables insulated with low density polyethylene (LDPE). As a result, for cables with lengths of 16 to 72 m, the maximum sensitivity is attained when the highest frequency of the inputted electromagnetic waves is 1.0 GHz or higher for coaxial cables, but around 600 to 800 MHz for dual or triple core cables.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信