Nur Fadzlin Binti Mohamad Nasaruddin, I. Elamvazuthi, N. H. H. M. Hanif
{"title":"克服气体探测器因受潮而故障报警","authors":"Nur Fadzlin Binti Mohamad Nasaruddin, I. Elamvazuthi, N. H. H. M. Hanif","doi":"10.1109/SCORED.2009.5442980","DOIUrl":null,"url":null,"abstract":"The issue of plant explosion due to gas leakage is a serious problem which impacts the lives of the personnel, damages plant equipments and incurs high cost for maintenance. As this issue is a high risk at hazardous place such as a combustible gas plant, there is an important need to use gas detector which functions to detect gas leakage at a particular area. However, some gas detectors are less reliable in detecting gas due to presence of other unwanted elements which may cause the instruments to malfunction. The objective of the study is to eliminate those unwanted elements in order to maintain the well functioning of the instrument. The paper discusses the Infrared signal absorption by combustible gas and solution to eliminate moisture trapped in gas detector.","PeriodicalId":443287,"journal":{"name":"2009 IEEE Student Conference on Research and Development (SCOReD)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":"{\"title\":\"Overcoming gas detector fault alarm due to moisture\",\"authors\":\"Nur Fadzlin Binti Mohamad Nasaruddin, I. Elamvazuthi, N. H. H. M. Hanif\",\"doi\":\"10.1109/SCORED.2009.5442980\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The issue of plant explosion due to gas leakage is a serious problem which impacts the lives of the personnel, damages plant equipments and incurs high cost for maintenance. As this issue is a high risk at hazardous place such as a combustible gas plant, there is an important need to use gas detector which functions to detect gas leakage at a particular area. However, some gas detectors are less reliable in detecting gas due to presence of other unwanted elements which may cause the instruments to malfunction. The objective of the study is to eliminate those unwanted elements in order to maintain the well functioning of the instrument. The paper discusses the Infrared signal absorption by combustible gas and solution to eliminate moisture trapped in gas detector.\",\"PeriodicalId\":443287,\"journal\":{\"name\":\"2009 IEEE Student Conference on Research and Development (SCOReD)\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-11-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE Student Conference on Research and Development (SCOReD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SCORED.2009.5442980\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE Student Conference on Research and Development (SCOReD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SCORED.2009.5442980","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Overcoming gas detector fault alarm due to moisture
The issue of plant explosion due to gas leakage is a serious problem which impacts the lives of the personnel, damages plant equipments and incurs high cost for maintenance. As this issue is a high risk at hazardous place such as a combustible gas plant, there is an important need to use gas detector which functions to detect gas leakage at a particular area. However, some gas detectors are less reliable in detecting gas due to presence of other unwanted elements which may cause the instruments to malfunction. The objective of the study is to eliminate those unwanted elements in order to maintain the well functioning of the instrument. The paper discusses the Infrared signal absorption by combustible gas and solution to eliminate moisture trapped in gas detector.