脑基视觉障碍患者的功能磁共振成像与视频自动视野测量相结合

M. Maciejewski, K. Ropella, E. DeYoe
{"title":"脑基视觉障碍患者的功能磁共振成像与视频自动视野测量相结合","authors":"M. Maciejewski, K. Ropella, E. DeYoe","doi":"10.1109/CNE.2005.1419695","DOIUrl":null,"url":null,"abstract":"For clinical diagnosis of brain-related vision deficits, it is advantageous to obtain behavioral visual field perimetry in conjunction with functional magnetic resonance imaging (fMRI) maps of visual cortex function. Ideally, these data should be obtained simultaneously to ensure that both measures are closely correlated. To facilitate this goal, we have developed a video automated perimeter (VAP) that will allow conventional or custom visual field testing inside the fMRI environment. To validate the system, data were obtained using both the VAP and a conventional Humphrey field analyzer (HFA) for 4 patients having localized visual field defects. Flashing spots of 0.4deg were presented on a grid of 76 test points (identical to the Humphrey 30-2 grid) using a modified staircase protocol to estimate detection thresholds. Overall, detection thresholds obtained with the two systems were similar though the VAP was 2 dB less sensitive, on average. Most importantly, though, the spatial pattern of visual sensitivity matched well in the two tests with a median cross correlation coefficient of 0.71, comparable to correlations obtained between repeated runs using the HFA. Thus the VAP system provides visual field maps comparable to those obtained with Humphrey perimetry but that can be administered between runs while the patient is in the MRI scanner, thus reducing test time and ensuring that both measures are obtained under closely matched conditions","PeriodicalId":113815,"journal":{"name":"Conference Proceedings. 2nd International IEEE EMBS Conference on Neural Engineering, 2005.","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Combining fMRI with Video Automated Perimetry in Patients with Brain-based Visual Impairments\",\"authors\":\"M. Maciejewski, K. Ropella, E. DeYoe\",\"doi\":\"10.1109/CNE.2005.1419695\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For clinical diagnosis of brain-related vision deficits, it is advantageous to obtain behavioral visual field perimetry in conjunction with functional magnetic resonance imaging (fMRI) maps of visual cortex function. Ideally, these data should be obtained simultaneously to ensure that both measures are closely correlated. To facilitate this goal, we have developed a video automated perimeter (VAP) that will allow conventional or custom visual field testing inside the fMRI environment. To validate the system, data were obtained using both the VAP and a conventional Humphrey field analyzer (HFA) for 4 patients having localized visual field defects. Flashing spots of 0.4deg were presented on a grid of 76 test points (identical to the Humphrey 30-2 grid) using a modified staircase protocol to estimate detection thresholds. Overall, detection thresholds obtained with the two systems were similar though the VAP was 2 dB less sensitive, on average. Most importantly, though, the spatial pattern of visual sensitivity matched well in the two tests with a median cross correlation coefficient of 0.71, comparable to correlations obtained between repeated runs using the HFA. Thus the VAP system provides visual field maps comparable to those obtained with Humphrey perimetry but that can be administered between runs while the patient is in the MRI scanner, thus reducing test time and ensuring that both measures are obtained under closely matched conditions\",\"PeriodicalId\":113815,\"journal\":{\"name\":\"Conference Proceedings. 2nd International IEEE EMBS Conference on Neural Engineering, 2005.\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-03-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Proceedings. 2nd International IEEE EMBS Conference on Neural Engineering, 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CNE.2005.1419695\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Proceedings. 2nd International IEEE EMBS Conference on Neural Engineering, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CNE.2005.1419695","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对于脑相关视力缺陷的临床诊断,结合功能磁共振成像(fMRI)获得行为视野视野测量是有利的。理想情况下,这些数据应同时获得,以确保两种测量密切相关。为了实现这一目标,我们开发了一种视频自动边界(VAP),它将允许在fMRI环境中进行常规或定制的视野测试。为了验证该系统,我们使用VAP和传统的Humphrey视野分析仪(HFA)对4例局限性视野缺损患者进行了数据采集。在76个测试点(与Humphrey 30-2网格相同)的网格上呈现0.4度的闪烁点,使用改进的阶梯协议来估计检测阈值。总体而言,两种系统获得的检测阈值相似,尽管VAP平均敏感度低2 dB。然而,最重要的是,视觉灵敏度的空间模式在两个测试中匹配得很好,中位交叉相关系数为0.71,与使用HFA重复运行之间获得的相关性相当。因此,VAP系统提供的视野图与Humphrey视野图相当,但可以在患者在MRI扫描仪中进行两次检查之间进行,从而减少了测试时间,并确保在密切匹配的条件下获得两种测量结果
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Combining fMRI with Video Automated Perimetry in Patients with Brain-based Visual Impairments
For clinical diagnosis of brain-related vision deficits, it is advantageous to obtain behavioral visual field perimetry in conjunction with functional magnetic resonance imaging (fMRI) maps of visual cortex function. Ideally, these data should be obtained simultaneously to ensure that both measures are closely correlated. To facilitate this goal, we have developed a video automated perimeter (VAP) that will allow conventional or custom visual field testing inside the fMRI environment. To validate the system, data were obtained using both the VAP and a conventional Humphrey field analyzer (HFA) for 4 patients having localized visual field defects. Flashing spots of 0.4deg were presented on a grid of 76 test points (identical to the Humphrey 30-2 grid) using a modified staircase protocol to estimate detection thresholds. Overall, detection thresholds obtained with the two systems were similar though the VAP was 2 dB less sensitive, on average. Most importantly, though, the spatial pattern of visual sensitivity matched well in the two tests with a median cross correlation coefficient of 0.71, comparable to correlations obtained between repeated runs using the HFA. Thus the VAP system provides visual field maps comparable to those obtained with Humphrey perimetry but that can be administered between runs while the patient is in the MRI scanner, thus reducing test time and ensuring that both measures are obtained under closely matched conditions
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信