利用VSI产生多正弦测试信号,用于同步电机的识别

T. Vandoorn, F. De Belie, T. Vyncke, J. Melkebeek, P. Lataire
{"title":"利用VSI产生多正弦测试信号,用于同步电机的识别","authors":"T. Vandoorn, F. De Belie, T. Vyncke, J. Melkebeek, P. Lataire","doi":"10.1109/ICELMACH.2008.4799910","DOIUrl":null,"url":null,"abstract":"Despite the effectiveness of the standstill frequency-response test or SSFR test in identifying accurate electrical machine models, it has the disadvantage of being a time consuming method. Therefore the use of a broadband signal is proposed instead of the excitation of only one frequency in the test signal and this sequentially for different signal frequencies. Furthermore, the test signals are often generated by using a waveform generator externally applied to the machine, which is not commonly available in the field. In this paper the generation of broadband test signals by using a voltage-source inverter (VSI) resulting in a multisine SSFR test is discussed. Using this multisine SSFR test the influence of saturation and cross-saturation on the q- and d-axis parameters can be swiftly evaluated.","PeriodicalId":416125,"journal":{"name":"2008 18th International Conference on Electrical Machines","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Generating multisinusoidal test signals by using a VSI for the identification of synchronous machines\",\"authors\":\"T. Vandoorn, F. De Belie, T. Vyncke, J. Melkebeek, P. Lataire\",\"doi\":\"10.1109/ICELMACH.2008.4799910\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Despite the effectiveness of the standstill frequency-response test or SSFR test in identifying accurate electrical machine models, it has the disadvantage of being a time consuming method. Therefore the use of a broadband signal is proposed instead of the excitation of only one frequency in the test signal and this sequentially for different signal frequencies. Furthermore, the test signals are often generated by using a waveform generator externally applied to the machine, which is not commonly available in the field. In this paper the generation of broadband test signals by using a voltage-source inverter (VSI) resulting in a multisine SSFR test is discussed. Using this multisine SSFR test the influence of saturation and cross-saturation on the q- and d-axis parameters can be swiftly evaluated.\",\"PeriodicalId\":416125,\"journal\":{\"name\":\"2008 18th International Conference on Electrical Machines\",\"volume\":\"20 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 18th International Conference on Electrical Machines\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICELMACH.2008.4799910\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 18th International Conference on Electrical Machines","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICELMACH.2008.4799910","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

尽管静止频率响应测试或SSFR测试在识别准确的电机模型方面是有效的,但它具有耗时的缺点。因此,建议使用宽带信号来代替测试信号中只有一个频率的激励,并依次对不同的信号频率进行激励。此外,测试信号通常是通过使用外部应用于机器的波形发生器产生的,这在现场通常是不可用的。本文讨论了利用电压源逆变器(VSI)产生宽带测试信号,从而实现多正弦SSFR测试。利用这种多正弦SSFR测试,可以快速评估饱和和交叉饱和对q轴和d轴参数的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Generating multisinusoidal test signals by using a VSI for the identification of synchronous machines
Despite the effectiveness of the standstill frequency-response test or SSFR test in identifying accurate electrical machine models, it has the disadvantage of being a time consuming method. Therefore the use of a broadband signal is proposed instead of the excitation of only one frequency in the test signal and this sequentially for different signal frequencies. Furthermore, the test signals are often generated by using a waveform generator externally applied to the machine, which is not commonly available in the field. In this paper the generation of broadband test signals by using a voltage-source inverter (VSI) resulting in a multisine SSFR test is discussed. Using this multisine SSFR test the influence of saturation and cross-saturation on the q- and d-axis parameters can be swiftly evaluated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信