树莓派驱动的电化学连续监测平台流动注射系统

Bruno Donato, Francesca Stradolini, Abuduwaili Tuoheti, F. Angiolini, D. Demarchi, G. Micheli, S. Carrara
{"title":"树莓派驱动的电化学连续监测平台流动注射系统","authors":"Bruno Donato, Francesca Stradolini, Abuduwaili Tuoheti, F. Angiolini, D. Demarchi, G. Micheli, S. Carrara","doi":"10.1109/BIOCAS.2017.8325134","DOIUrl":null,"url":null,"abstract":"The degree of interest in bio-sensing platforms brings to the forefront a corresponding need for effective testing of their capabilities. This necessity is even more crucial when examining the properties of a sensor for continuous monitoring of a concentration trend in time, before in vivo implementations. Moreover, in the framework of personalised medical practices, it is imperative to introduce a robust way to represent and parametrise the highly variable responses of human metabolism. The aim of this paper is to propose a novel solution for the design of an automatic flow-injection environment that can assess the performance of systems for continuous monitoring. The setup is also approved for successfully reproducing a paracetamol concentration trend in buffer solution.","PeriodicalId":361477,"journal":{"name":"2017 IEEE Biomedical Circuits and Systems Conference (BioCAS)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Raspberry Pi driven flow-injection system for electrochemical continuous monitoring platforms\",\"authors\":\"Bruno Donato, Francesca Stradolini, Abuduwaili Tuoheti, F. Angiolini, D. Demarchi, G. Micheli, S. Carrara\",\"doi\":\"10.1109/BIOCAS.2017.8325134\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The degree of interest in bio-sensing platforms brings to the forefront a corresponding need for effective testing of their capabilities. This necessity is even more crucial when examining the properties of a sensor for continuous monitoring of a concentration trend in time, before in vivo implementations. Moreover, in the framework of personalised medical practices, it is imperative to introduce a robust way to represent and parametrise the highly variable responses of human metabolism. The aim of this paper is to propose a novel solution for the design of an automatic flow-injection environment that can assess the performance of systems for continuous monitoring. The setup is also approved for successfully reproducing a paracetamol concentration trend in buffer solution.\",\"PeriodicalId\":361477,\"journal\":{\"name\":\"2017 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIOCAS.2017.8325134\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE Biomedical Circuits and Systems Conference (BioCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOCAS.2017.8325134","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

对生物传感平台的兴趣程度带来了对其能力进行有效测试的相应需求。在体内实施之前,在检查传感器的特性以及时连续监测浓度趋势时,这种必要性更为重要。此外,在个性化医疗实践的框架中,引入一种鲁棒的方法来表示和参数化人体代谢的高度可变反应是势在必行的。本文的目的是提出一种新的解决方案来设计一个自动流动注射环境,可以评估系统的性能,以进行连续监测。该装置也被批准用于成功重现缓冲溶液中扑热息痛的浓度趋势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Raspberry Pi driven flow-injection system for electrochemical continuous monitoring platforms
The degree of interest in bio-sensing platforms brings to the forefront a corresponding need for effective testing of their capabilities. This necessity is even more crucial when examining the properties of a sensor for continuous monitoring of a concentration trend in time, before in vivo implementations. Moreover, in the framework of personalised medical practices, it is imperative to introduce a robust way to represent and parametrise the highly variable responses of human metabolism. The aim of this paper is to propose a novel solution for the design of an automatic flow-injection environment that can assess the performance of systems for continuous monitoring. The setup is also approved for successfully reproducing a paracetamol concentration trend in buffer solution.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信