直接循环核电站稳定性分析

D. Buden, R. Miller
{"title":"直接循环核电站稳定性分析","authors":"D. Buden, R. Miller","doi":"10.1109/TAC.1961.1105189","DOIUrl":null,"url":null,"abstract":"A power plant with a heat exchanger such as a nuclear reactor substituted for the conventional chemical interburn-ers in a jet engine will cause a considerable change in dynamic performance. The instantaneous power generated by the heat source is not the same as the instantaneous power delivered to the turbine. The basic control problems are analyzed using fixed control parameters and partial derivatives around a given operating point. A mathematical criterion is developed and correlated with power plant test data. An understanding of the inherent limitations of combining a reactor, or any heat exchanger having a thermal lag, with a basic jet engine makes it possible to devise a means of control. The introduction of an effective operational speed control makes it possible to operate a complete power plant under any desired condition.","PeriodicalId":226447,"journal":{"name":"Ire Transactions on Automatic Control","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1961-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Direct cycle nuclear power plant stability analysis\",\"authors\":\"D. Buden, R. Miller\",\"doi\":\"10.1109/TAC.1961.1105189\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A power plant with a heat exchanger such as a nuclear reactor substituted for the conventional chemical interburn-ers in a jet engine will cause a considerable change in dynamic performance. The instantaneous power generated by the heat source is not the same as the instantaneous power delivered to the turbine. The basic control problems are analyzed using fixed control parameters and partial derivatives around a given operating point. A mathematical criterion is developed and correlated with power plant test data. An understanding of the inherent limitations of combining a reactor, or any heat exchanger having a thermal lag, with a basic jet engine makes it possible to devise a means of control. The introduction of an effective operational speed control makes it possible to operate a complete power plant under any desired condition.\",\"PeriodicalId\":226447,\"journal\":{\"name\":\"Ire Transactions on Automatic Control\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1961-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ire Transactions on Automatic Control\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TAC.1961.1105189\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ire Transactions on Automatic Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TAC.1961.1105189","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

用核反应堆等热交换器代替喷气发动机中传统的化学间燃烧器,将使动力性能发生相当大的变化。热源产生的瞬时功率与输送到涡轮的瞬时功率是不一样的。利用固定控制参数和给定工作点周围的偏导数分析了基本控制问题。建立了一个数学准则,并与电厂试验数据相关联。对反应堆或任何具有热滞后的热交换器与基本喷气发动机相结合的固有局限性的理解,使设计一种控制手段成为可能。引入有效的运行速度控制使得在任何期望的条件下运行完整的发电厂成为可能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Direct cycle nuclear power plant stability analysis
A power plant with a heat exchanger such as a nuclear reactor substituted for the conventional chemical interburn-ers in a jet engine will cause a considerable change in dynamic performance. The instantaneous power generated by the heat source is not the same as the instantaneous power delivered to the turbine. The basic control problems are analyzed using fixed control parameters and partial derivatives around a given operating point. A mathematical criterion is developed and correlated with power plant test data. An understanding of the inherent limitations of combining a reactor, or any heat exchanger having a thermal lag, with a basic jet engine makes it possible to devise a means of control. The introduction of an effective operational speed control makes it possible to operate a complete power plant under any desired condition.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信