Yan Hu, Zhongwei Liang, Qian Chen, Shijie Feng, C. Zuo
{"title":"双远心透镜在Scheimpflug条件下的简化成像模型及其标定","authors":"Yan Hu, Zhongwei Liang, Qian Chen, Shijie Feng, C. Zuo","doi":"10.1117/12.2586423","DOIUrl":null,"url":null,"abstract":"In the lens-based imaging model, the Scheimpflug principle is expressed as the object plane, the image plane, and the lens plane intersect in a line. With this principle, the object surface in front of the lens can be tilted by installing a tilted sensor, thereby significantly extending the axial distribution of the clear-imaging area. In order to calibrate the bi-telecentric lens under the Scheimpflug condition, we derived a concise imaging model, and the corresponding calibration method without solving the rotation or tilt angle is proposed. The re-projection error is calculated in the experiment to verify the effectiveness of our method.","PeriodicalId":370739,"journal":{"name":"International Conference on Photonics and Optical Engineering and the Annual West China Photonics Conference","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A simplified imaging model of bi-telecentric lenses under Scheimpflug condition and its calibration\",\"authors\":\"Yan Hu, Zhongwei Liang, Qian Chen, Shijie Feng, C. Zuo\",\"doi\":\"10.1117/12.2586423\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the lens-based imaging model, the Scheimpflug principle is expressed as the object plane, the image plane, and the lens plane intersect in a line. With this principle, the object surface in front of the lens can be tilted by installing a tilted sensor, thereby significantly extending the axial distribution of the clear-imaging area. In order to calibrate the bi-telecentric lens under the Scheimpflug condition, we derived a concise imaging model, and the corresponding calibration method without solving the rotation or tilt angle is proposed. The re-projection error is calculated in the experiment to verify the effectiveness of our method.\",\"PeriodicalId\":370739,\"journal\":{\"name\":\"International Conference on Photonics and Optical Engineering and the Annual West China Photonics Conference\",\"volume\":\"22 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Conference on Photonics and Optical Engineering and the Annual West China Photonics Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2586423\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Photonics and Optical Engineering and the Annual West China Photonics Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2586423","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A simplified imaging model of bi-telecentric lenses under Scheimpflug condition and its calibration
In the lens-based imaging model, the Scheimpflug principle is expressed as the object plane, the image plane, and the lens plane intersect in a line. With this principle, the object surface in front of the lens can be tilted by installing a tilted sensor, thereby significantly extending the axial distribution of the clear-imaging area. In order to calibrate the bi-telecentric lens under the Scheimpflug condition, we derived a concise imaging model, and the corresponding calibration method without solving the rotation or tilt angle is proposed. The re-projection error is calculated in the experiment to verify the effectiveness of our method.