{"title":"基于Cover试验的斜视自动刺激同步跟踪系统","authors":"Yang Zheng, Hong Fu, Bin Li, W. Lo, Bin Li","doi":"10.1109/ICIIBMS.2018.8549953","DOIUrl":null,"url":null,"abstract":"Strabismus is a common vision disorder that affects around 4% of the population, bringing about unpleasant influences on people's health and quality of life. The cover test is one of the exams for detecting this pathology, which is considered as the golden standard method. However, the subjectivity of the ophthalmologist conducting the cover test could lead to uncertainties and limitations to the result of strabismus assessment. Nowadays computer-aid methods have been used to assist ophthalmological diagnosis and therapy, whereas the development and use of the high-tech is not a general reality within the sub-specialty of strabismus. In this study, an automatic stimulus module controlled by the micro-control-unit is used to generate the cover action of the occluder and the imaging devices are used to simultaneously monitor and record the movement of the eyes. With the proposed system and algorithm, the presence and type of strabismus can be generated automatically, which makes the diagnosis of strabismus objective, automatic and highly efficient.","PeriodicalId":430326,"journal":{"name":"2018 International Conference on Intelligent Informatics and Biomedical Sciences (ICIIBMS)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"An Automatic Stimulus and Synchronous Tracking System for Strabismus Assessment based on Cover Test\",\"authors\":\"Yang Zheng, Hong Fu, Bin Li, W. Lo, Bin Li\",\"doi\":\"10.1109/ICIIBMS.2018.8549953\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Strabismus is a common vision disorder that affects around 4% of the population, bringing about unpleasant influences on people's health and quality of life. The cover test is one of the exams for detecting this pathology, which is considered as the golden standard method. However, the subjectivity of the ophthalmologist conducting the cover test could lead to uncertainties and limitations to the result of strabismus assessment. Nowadays computer-aid methods have been used to assist ophthalmological diagnosis and therapy, whereas the development and use of the high-tech is not a general reality within the sub-specialty of strabismus. In this study, an automatic stimulus module controlled by the micro-control-unit is used to generate the cover action of the occluder and the imaging devices are used to simultaneously monitor and record the movement of the eyes. With the proposed system and algorithm, the presence and type of strabismus can be generated automatically, which makes the diagnosis of strabismus objective, automatic and highly efficient.\",\"PeriodicalId\":430326,\"journal\":{\"name\":\"2018 International Conference on Intelligent Informatics and Biomedical Sciences (ICIIBMS)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Conference on Intelligent Informatics and Biomedical Sciences (ICIIBMS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIIBMS.2018.8549953\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Intelligent Informatics and Biomedical Sciences (ICIIBMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIIBMS.2018.8549953","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

斜视是一种常见的视力障碍,影响了约4%的人口,给人们的健康和生活质量带来了不愉快的影响。覆盖测试是检测这种病理的一种测试,被认为是黄金标准方法。然而,眼科医生进行覆盖测试的主观性可能导致斜视评估结果的不确定性和局限性。目前,计算机辅助方法已被用于辅助眼科诊断和治疗,然而,在斜视亚专科中,高科技的发展和使用并不是普遍的现实。在本研究中,通过微控单元控制的自动刺激模块产生遮挡器的遮挡动作,同时使用成像设备监测和记录眼睛的运动。该系统和算法能够自动生成斜视的存在和类型,使斜视诊断客观、自动、高效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An Automatic Stimulus and Synchronous Tracking System for Strabismus Assessment based on Cover Test
Strabismus is a common vision disorder that affects around 4% of the population, bringing about unpleasant influences on people's health and quality of life. The cover test is one of the exams for detecting this pathology, which is considered as the golden standard method. However, the subjectivity of the ophthalmologist conducting the cover test could lead to uncertainties and limitations to the result of strabismus assessment. Nowadays computer-aid methods have been used to assist ophthalmological diagnosis and therapy, whereas the development and use of the high-tech is not a general reality within the sub-specialty of strabismus. In this study, an automatic stimulus module controlled by the micro-control-unit is used to generate the cover action of the occluder and the imaging devices are used to simultaneously monitor and record the movement of the eyes. With the proposed system and algorithm, the presence and type of strabismus can be generated automatically, which makes the diagnosis of strabismus objective, automatic and highly efficient.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信