{"title":"gtem细胞中电视监视器的敏感性测定","authors":"K. Malaric, N. Majurec, J. Bartolić","doi":"10.1109/ISEMC.2003.1236694","DOIUrl":null,"url":null,"abstract":"Electronic devices share the same resources, such as frequency and space. Their ability to sustain the interference from each other is susceptibility. It is important to find which levels of interference disrupt the normal operation of those devices. Is a portable television monitor sensitive to the interference from other electronic equipment operating at the same frequencies? What are the signal levels that will cause the interference? To solve this problem, a GTEM-cell structure was used. It has homogeneous electromagnetic field area where the equipment under test is placed. Finite element method is used to model the loaded and unloaded GTEM-cell. The interference is measured using the signal generator, Hewlett Packard 8640B and Tektronix CFG250 function generator. The insertion of the TV monitor changes the electric from 2.25 to 1.25 mV/m, so the measured results must be calibrated. The sensitivity is 97 dB [ /spl mu/V/m ] for lower frequency and dropping to 80 dB [ /spl mu/V/m ] for higher frequencies. Since they are higher than the C.I.S.P.R and FCC levels for radiated emissions for A and B class equipment at the test distance of 10 m, the tested TV monitor meets the standard requirements.","PeriodicalId":359422,"journal":{"name":"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Susceptibility measurement of television monitor in GTEM-cell\",\"authors\":\"K. Malaric, N. Majurec, J. Bartolić\",\"doi\":\"10.1109/ISEMC.2003.1236694\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electronic devices share the same resources, such as frequency and space. Their ability to sustain the interference from each other is susceptibility. It is important to find which levels of interference disrupt the normal operation of those devices. Is a portable television monitor sensitive to the interference from other electronic equipment operating at the same frequencies? What are the signal levels that will cause the interference? To solve this problem, a GTEM-cell structure was used. It has homogeneous electromagnetic field area where the equipment under test is placed. Finite element method is used to model the loaded and unloaded GTEM-cell. The interference is measured using the signal generator, Hewlett Packard 8640B and Tektronix CFG250 function generator. The insertion of the TV monitor changes the electric from 2.25 to 1.25 mV/m, so the measured results must be calibrated. The sensitivity is 97 dB [ /spl mu/V/m ] for lower frequency and dropping to 80 dB [ /spl mu/V/m ] for higher frequencies. Since they are higher than the C.I.S.P.R and FCC levels for radiated emissions for A and B class equipment at the test distance of 10 m, the tested TV monitor meets the standard requirements.\",\"PeriodicalId\":359422,\"journal\":{\"name\":\"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-10-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.2003.1236694\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2003.1236694","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
电子设备共享相同的资源,如频率和空间。它们承受彼此干扰的能力就是易感性。重要的是要找出哪些程度的干扰会破坏这些设备的正常运行。便携式电视监视器对其他在相同频率工作的电子设备的干扰是否敏感?会造成干扰的信号电平是多少?为了解决这个问题,使用了gtem细胞结构。被测设备所在的电磁场区域均匀。采用有限元法对加载和卸载的gtem单元进行了建模。干扰测量使用信号发生器,惠普8640B和泰克CFG250函数发生器。电视监视器的插入使电流从2.25 mV/m变为1.25 mV/m,因此必须对测量结果进行校准。低频灵敏度为97 dB [/spl mu/V/m],高频灵敏度降至80 dB [/spl mu/V/m]。测试距离为10 m时,A类和B类设备的辐射发射高于csis / pr和FCC标准,因此测试的电视监视器符合标准要求。
Susceptibility measurement of television monitor in GTEM-cell
Electronic devices share the same resources, such as frequency and space. Their ability to sustain the interference from each other is susceptibility. It is important to find which levels of interference disrupt the normal operation of those devices. Is a portable television monitor sensitive to the interference from other electronic equipment operating at the same frequencies? What are the signal levels that will cause the interference? To solve this problem, a GTEM-cell structure was used. It has homogeneous electromagnetic field area where the equipment under test is placed. Finite element method is used to model the loaded and unloaded GTEM-cell. The interference is measured using the signal generator, Hewlett Packard 8640B and Tektronix CFG250 function generator. The insertion of the TV monitor changes the electric from 2.25 to 1.25 mV/m, so the measured results must be calibrated. The sensitivity is 97 dB [ /spl mu/V/m ] for lower frequency and dropping to 80 dB [ /spl mu/V/m ] for higher frequencies. Since they are higher than the C.I.S.P.R and FCC levels for radiated emissions for A and B class equipment at the test distance of 10 m, the tested TV monitor meets the standard requirements.