血浆样品中主要神经认知障碍检测的高光谱成像

Raquel León, Beatriz Martínez-Vega, H. Fabelo, S. Ortega, G. Callicó, Francisco Balea-Fernández, C. B. Sieyro
{"title":"血浆样品中主要神经认知障碍检测的高光谱成像","authors":"Raquel León, Beatriz Martínez-Vega, H. Fabelo, S. Ortega, G. Callicó, Francisco Balea-Fernández, C. B. Sieyro","doi":"10.1109/DCIS51330.2020.9268625","DOIUrl":null,"url":null,"abstract":"Neurocognitive disorders (NCD) affect over 50 million people globally. The detection biomarkers using brain imaging or cerebrospinal fluid are expensive procedures. Blood-based biomarkers such as plasma or serum present a cost-effective alternative. The work presented in this paper is focused on the use of hyperspectral (HS) imaging (HSI) to classify plasma samples in order to discriminate between patients with major NCD and healthy control subjects. HS images of plasma samples were obtained using a SWIR (Short-Wave Infrared) camera able to capture 273 bands within the 900-2,500 nm spectral range. A preliminary HSI database was obtained with 20 major NCD samples and 20 control samples. This data was segmented and classified using pixel-wise supervised classification algorithms, achieving 75% sensitivity and 100% specificity results with the best classifier in the test set.","PeriodicalId":186963,"journal":{"name":"2020 XXXV Conference on Design of Circuits and Integrated Systems (DCIS)","volume":"319 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Hyperspectral Imaging for Major Neurocognitive Disorder Detection in Plasma Samples\",\"authors\":\"Raquel León, Beatriz Martínez-Vega, H. Fabelo, S. Ortega, G. Callicó, Francisco Balea-Fernández, C. B. Sieyro\",\"doi\":\"10.1109/DCIS51330.2020.9268625\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Neurocognitive disorders (NCD) affect over 50 million people globally. The detection biomarkers using brain imaging or cerebrospinal fluid are expensive procedures. Blood-based biomarkers such as plasma or serum present a cost-effective alternative. The work presented in this paper is focused on the use of hyperspectral (HS) imaging (HSI) to classify plasma samples in order to discriminate between patients with major NCD and healthy control subjects. HS images of plasma samples were obtained using a SWIR (Short-Wave Infrared) camera able to capture 273 bands within the 900-2,500 nm spectral range. A preliminary HSI database was obtained with 20 major NCD samples and 20 control samples. This data was segmented and classified using pixel-wise supervised classification algorithms, achieving 75% sensitivity and 100% specificity results with the best classifier in the test set.\",\"PeriodicalId\":186963,\"journal\":{\"name\":\"2020 XXXV Conference on Design of Circuits and Integrated Systems (DCIS)\",\"volume\":\"319 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 XXXV Conference on Design of Circuits and Integrated Systems (DCIS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DCIS51330.2020.9268625\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 XXXV Conference on Design of Circuits and Integrated Systems (DCIS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DCIS51330.2020.9268625","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

神经认知障碍(NCD)影响着全球5000多万人。使用脑成像或脑脊液检测生物标志物是昂贵的程序。以血液为基础的生物标志物,如血浆或血清,是一种具有成本效益的替代方法。本文的工作重点是利用高光谱(HS)成像(HSI)对血浆样本进行分类,以区分非传染性疾病患者和健康对照者。等离子体样品的HS图像使用SWIR(短波红外)相机获得,该相机能够捕获900-2,500 nm光谱范围内的273个波段。初步建立了20个主要非传染性疾病样本和20个对照样本的HSI数据库。该数据使用逐像素监督分类算法进行分割和分类,使用测试集中最好的分类器获得75%的灵敏度和100%的特异性结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Hyperspectral Imaging for Major Neurocognitive Disorder Detection in Plasma Samples
Neurocognitive disorders (NCD) affect over 50 million people globally. The detection biomarkers using brain imaging or cerebrospinal fluid are expensive procedures. Blood-based biomarkers such as plasma or serum present a cost-effective alternative. The work presented in this paper is focused on the use of hyperspectral (HS) imaging (HSI) to classify plasma samples in order to discriminate between patients with major NCD and healthy control subjects. HS images of plasma samples were obtained using a SWIR (Short-Wave Infrared) camera able to capture 273 bands within the 900-2,500 nm spectral range. A preliminary HSI database was obtained with 20 major NCD samples and 20 control samples. This data was segmented and classified using pixel-wise supervised classification algorithms, achieving 75% sensitivity and 100% specificity results with the best classifier in the test set.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信