振动对超滤效率的影响

Szabolcs Gyula Szerencsés, S. Beszédes, Z. László, G. Veréb, B. Szegedi, Zsuzsanna Hovorkáné Horváth, C. Hodúr, G. Rákhely, S. Kertész
{"title":"振动对超滤效率的影响","authors":"Szabolcs Gyula Szerencsés, S. Beszédes, Z. László, G. Veréb, B. Szegedi, Zsuzsanna Hovorkáné Horváth, C. Hodúr, G. Rákhely, S. Kertész","doi":"10.14232/analecta.2021.1.37-44","DOIUrl":null,"url":null,"abstract":"Nowadays, several environmental challenges are present to cope with. One with outstanding importance is the protection of our water supplies, therefore examination of wastewater treatment technology is a priority, especially in the European Union. In this work, the effect of membrane module vibration amplitude on the efficiency of ultrafiltration (UF) was investigated in a vibratory shear enhanced membrane filtration system. Based on the results of model dairy effluent UF and statistical analysis, the maximum vibration level available resulted in the most efficient filtration process, due to the most significant reduction of membrane fouling. From our results it was observed that the permeate fluxes more than doubled, specific energy demand was roughly halved, with almost identical retentions for organic matter, and total filtration resistance was reduced to less than half. Results also showed that setting the optimal operating parameters, an advantageous, efficiency focused, and sustainable wastewater treatment technology can be established.","PeriodicalId":213647,"journal":{"name":"Analecta Technica Szegedinensia","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Effect of vibration on the efficiency of ultrafiltration\",\"authors\":\"Szabolcs Gyula Szerencsés, S. Beszédes, Z. László, G. Veréb, B. Szegedi, Zsuzsanna Hovorkáné Horváth, C. Hodúr, G. Rákhely, S. Kertész\",\"doi\":\"10.14232/analecta.2021.1.37-44\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Nowadays, several environmental challenges are present to cope with. One with outstanding importance is the protection of our water supplies, therefore examination of wastewater treatment technology is a priority, especially in the European Union. In this work, the effect of membrane module vibration amplitude on the efficiency of ultrafiltration (UF) was investigated in a vibratory shear enhanced membrane filtration system. Based on the results of model dairy effluent UF and statistical analysis, the maximum vibration level available resulted in the most efficient filtration process, due to the most significant reduction of membrane fouling. From our results it was observed that the permeate fluxes more than doubled, specific energy demand was roughly halved, with almost identical retentions for organic matter, and total filtration resistance was reduced to less than half. Results also showed that setting the optimal operating parameters, an advantageous, efficiency focused, and sustainable wastewater treatment technology can be established.\",\"PeriodicalId\":213647,\"journal\":{\"name\":\"Analecta Technica Szegedinensia\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analecta Technica Szegedinensia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14232/analecta.2021.1.37-44\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analecta Technica Szegedinensia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14232/analecta.2021.1.37-44","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

如今,有几个环境挑战需要应对。其中一个非常重要的是保护我们的供水,因此对废水处理技术的研究是一个优先事项,特别是在欧洲联盟。在振动剪切增强膜过滤系统中,研究了膜组件振动幅值对超滤效率的影响。根据模型乳业出水超滤的结果和统计分析,由于膜污染的减少最显著,可用的最大振动水平导致了最有效的过滤过程。从我们的结果中可以观察到,渗透通量增加了一倍以上,比能量需求大约减少了一半,有机物的保留率几乎相同,总过滤阻力减少到一半以下。结果还表明,通过设定最佳操作参数,可以建立具有优势、高效、可持续的废水处理工艺。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of vibration on the efficiency of ultrafiltration
Nowadays, several environmental challenges are present to cope with. One with outstanding importance is the protection of our water supplies, therefore examination of wastewater treatment technology is a priority, especially in the European Union. In this work, the effect of membrane module vibration amplitude on the efficiency of ultrafiltration (UF) was investigated in a vibratory shear enhanced membrane filtration system. Based on the results of model dairy effluent UF and statistical analysis, the maximum vibration level available resulted in the most efficient filtration process, due to the most significant reduction of membrane fouling. From our results it was observed that the permeate fluxes more than doubled, specific energy demand was roughly halved, with almost identical retentions for organic matter, and total filtration resistance was reduced to less than half. Results also showed that setting the optimal operating parameters, an advantageous, efficiency focused, and sustainable wastewater treatment technology can be established.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信