对MP2RAGE部分体积估计模型的推广,以解释7T时B1+的不均匀性

J. Beaumont, O. Acosta, P. Raniga, G. Gambarota, J. Fripp
{"title":"对MP2RAGE部分体积估计模型的推广,以解释7T时B1+的不均匀性","authors":"J. Beaumont, O. Acosta, P. Raniga, G. Gambarota, J. Fripp","doi":"10.1109/ISBI48211.2021.9434089","DOIUrl":null,"url":null,"abstract":"Brain morphometry performed with magnetic resonance (MR) imaging is affected by partial volume (PV) effects when single voxels contain the signal from two different tissues. This paper proposes a generalization of the MP2 RAGE sequence PV estimation model which accounts for transmitted magnetic field $(B1^{+})$ inhomogeneities at 7T. Our simulation experiments demonstrated that the PV estimation error of the proposed model is significantly lower than the error obtained with the same model neglecting $B1^{+}$ inhomogeneities (p<0.0001). The accuracy and precision of the $B1^{+}$ model (acc=92.0%, prec=89.6%) was significantly increased compared to the non $B1^{+}$ model (acc=69.8%, prec=65.4%). This highlights the importance of accounting for $B1^{+}$ inhomogeneities when computing PV on MP2RAGE data, which would otherwise limit the accuracy of brain morphometry at 7T.","PeriodicalId":372939,"journal":{"name":"2021 IEEE 18th International Symposium on Biomedical Imaging (ISBI)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Towards a generalization of the MP2RAGE partial volume estimation model to account for B1+ inhomogeneities at 7T\",\"authors\":\"J. Beaumont, O. Acosta, P. Raniga, G. Gambarota, J. Fripp\",\"doi\":\"10.1109/ISBI48211.2021.9434089\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Brain morphometry performed with magnetic resonance (MR) imaging is affected by partial volume (PV) effects when single voxels contain the signal from two different tissues. This paper proposes a generalization of the MP2 RAGE sequence PV estimation model which accounts for transmitted magnetic field $(B1^{+})$ inhomogeneities at 7T. Our simulation experiments demonstrated that the PV estimation error of the proposed model is significantly lower than the error obtained with the same model neglecting $B1^{+}$ inhomogeneities (p<0.0001). The accuracy and precision of the $B1^{+}$ model (acc=92.0%, prec=89.6%) was significantly increased compared to the non $B1^{+}$ model (acc=69.8%, prec=65.4%). This highlights the importance of accounting for $B1^{+}$ inhomogeneities when computing PV on MP2RAGE data, which would otherwise limit the accuracy of brain morphometry at 7T.\",\"PeriodicalId\":372939,\"journal\":{\"name\":\"2021 IEEE 18th International Symposium on Biomedical Imaging (ISBI)\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE 18th International Symposium on Biomedical Imaging (ISBI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISBI48211.2021.9434089\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 18th International Symposium on Biomedical Imaging (ISBI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISBI48211.2021.9434089","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

当单个体素包含来自两个不同组织的信号时,用磁共振(MR)成像进行的脑形态测量受到部分体积(PV)效应的影响。本文提出了考虑7T发射磁场$(B1^{+})$不均匀性的MP2 RAGE序列PV估计模型的推广。我们的仿真实验表明,该模型的PV估计误差显著低于忽略$B1^{+}$不均匀性的相同模型所获得的误差(p<0.0001)。与非$B1^{+}$模型(acc=69.8%, prec=65.4%)相比,$B1^{+}$模型的准确度和精密度(acc=92.0%, prec=89.6%)显著提高。这突出了在MP2RAGE数据上计算PV时考虑$B1^{+}$不均匀性的重要性,否则将限制7T脑形态测量的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Towards a generalization of the MP2RAGE partial volume estimation model to account for B1+ inhomogeneities at 7T
Brain morphometry performed with magnetic resonance (MR) imaging is affected by partial volume (PV) effects when single voxels contain the signal from two different tissues. This paper proposes a generalization of the MP2 RAGE sequence PV estimation model which accounts for transmitted magnetic field $(B1^{+})$ inhomogeneities at 7T. Our simulation experiments demonstrated that the PV estimation error of the proposed model is significantly lower than the error obtained with the same model neglecting $B1^{+}$ inhomogeneities (p<0.0001). The accuracy and precision of the $B1^{+}$ model (acc=92.0%, prec=89.6%) was significantly increased compared to the non $B1^{+}$ model (acc=69.8%, prec=65.4%). This highlights the importance of accounting for $B1^{+}$ inhomogeneities when computing PV on MP2RAGE data, which would otherwise limit the accuracy of brain morphometry at 7T.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信