一种减小CT扫描仪局部体积平均伪影新方法的可行性研究

Hossein ARABI, A. K. Kamali Asl
{"title":"一种减小CT扫描仪局部体积平均伪影新方法的可行性研究","authors":"Hossein ARABI, A. K. Kamali Asl","doi":"10.1109/ICBME.2010.5704968","DOIUrl":null,"url":null,"abstract":"Partial volume averaging is one of the most prevalent artifacts in computed tomography (CT) that threatens the diagnostic interpretation by giving the misleading density of a voxel. This paper proposes a novel approach for reducing of partial volume averaging artifact in CT called dual scan method. The idea behind this work is to acquire two sinograms of the object while detector is slightly shifted in x-axis. Then a computer program simultaneously processes the two sinograms and extracts a new sinogram with double spatial resolution and less partial volume artifact. To evaluate this method, a model based on an actual CT scanner was simulated in GATE Monte Carlo code. An exclusive phantom was designed for investigation of partial volume averaging artifact. The phantom consisted of two materials with densities of 1.2 and 1.6 g/cm3. Because of partial volume averaging artifact the reconstructed image of the phantom revealed the density of 1.4 g/cm3 and also the spatial resolution of the system obtained 0.4 mm. After applying the dual scan method to the CT scanner, not only did the spatial resolution of the system improved to 0.2 mm but also the partial volume averaging artifact decreased up to 50% and density of each materials of the phantom was detected exactly.","PeriodicalId":377764,"journal":{"name":"2010 17th Iranian Conference of Biomedical Engineering (ICBME)","volume":"225 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":"{\"title\":\"Feasibility study of a new approach for reducing of partial volume averaging artifact in CT scanner\",\"authors\":\"Hossein ARABI, A. K. Kamali Asl\",\"doi\":\"10.1109/ICBME.2010.5704968\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Partial volume averaging is one of the most prevalent artifacts in computed tomography (CT) that threatens the diagnostic interpretation by giving the misleading density of a voxel. This paper proposes a novel approach for reducing of partial volume averaging artifact in CT called dual scan method. The idea behind this work is to acquire two sinograms of the object while detector is slightly shifted in x-axis. Then a computer program simultaneously processes the two sinograms and extracts a new sinogram with double spatial resolution and less partial volume artifact. To evaluate this method, a model based on an actual CT scanner was simulated in GATE Monte Carlo code. An exclusive phantom was designed for investigation of partial volume averaging artifact. The phantom consisted of two materials with densities of 1.2 and 1.6 g/cm3. Because of partial volume averaging artifact the reconstructed image of the phantom revealed the density of 1.4 g/cm3 and also the spatial resolution of the system obtained 0.4 mm. After applying the dual scan method to the CT scanner, not only did the spatial resolution of the system improved to 0.2 mm but also the partial volume averaging artifact decreased up to 50% and density of each materials of the phantom was detected exactly.\",\"PeriodicalId\":377764,\"journal\":{\"name\":\"2010 17th Iranian Conference of Biomedical Engineering (ICBME)\",\"volume\":\"225 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 17th Iranian Conference of Biomedical Engineering (ICBME)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICBME.2010.5704968\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 17th Iranian Conference of Biomedical Engineering (ICBME)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBME.2010.5704968","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

摘要

部分体积平均是计算机断层扫描(CT)中最常见的伪影之一,它通过给出误导的体素密度来威胁诊断解释。本文提出了一种新的减小CT局部体积平均伪影的方法——双重扫描法。这项工作背后的想法是,当探测器在x轴上轻微移动时,获取物体的两个图像。然后由计算机程序对两个正弦图同时进行处理,提取出具有双倍空间分辨率和较少局部体积伪影的新正弦图。为了验证该方法的有效性,在GATE蒙特卡罗代码中对基于实际CT扫描仪的模型进行了仿真。为研究局部体积平均伪影,设计了一种专用伪影。模体由密度分别为1.2和1.6 g/cm3的两种材料组成。由于部分体积平均伪影的存在,重建图像的密度为1.4 g/cm3,系统的空间分辨率为0.4 mm。将双扫描方法应用于CT扫描仪后,不仅系统的空间分辨率提高到0.2 mm,而且局部体积平均伪影减少了50%,并且准确地检测到幻体各材料的密度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Feasibility study of a new approach for reducing of partial volume averaging artifact in CT scanner
Partial volume averaging is one of the most prevalent artifacts in computed tomography (CT) that threatens the diagnostic interpretation by giving the misleading density of a voxel. This paper proposes a novel approach for reducing of partial volume averaging artifact in CT called dual scan method. The idea behind this work is to acquire two sinograms of the object while detector is slightly shifted in x-axis. Then a computer program simultaneously processes the two sinograms and extracts a new sinogram with double spatial resolution and less partial volume artifact. To evaluate this method, a model based on an actual CT scanner was simulated in GATE Monte Carlo code. An exclusive phantom was designed for investigation of partial volume averaging artifact. The phantom consisted of two materials with densities of 1.2 and 1.6 g/cm3. Because of partial volume averaging artifact the reconstructed image of the phantom revealed the density of 1.4 g/cm3 and also the spatial resolution of the system obtained 0.4 mm. After applying the dual scan method to the CT scanner, not only did the spatial resolution of the system improved to 0.2 mm but also the partial volume averaging artifact decreased up to 50% and density of each materials of the phantom was detected exactly.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信