基于元启发式/人工智能技术的多区域电力系统负荷频率控制

Junaid Hussain Lanker, Ravi Bhushan, Neeraj Gupta
{"title":"基于元启发式/人工智能技术的多区域电力系统负荷频率控制","authors":"Junaid Hussain Lanker, Ravi Bhushan, Neeraj Gupta","doi":"10.1109/ICICCSP53532.2022.9862473","DOIUrl":null,"url":null,"abstract":"This paper presents multi area load frequency control (LFC) using artificial intelligence techniques in a power system comprising of non-reheat thermal power units for a three area interconnected power system. In this proposed scheme, fuzzy logic, Artificial Neural Network and Genetic Algorithm technique has been used to tune the classical PID controller for each area. Step load disturbance has been applied to assess its consequence on the dynamic performance of power system. The results are compared and appreciable change i.e minimum overshoot/undershoot, less settling time and a better response is achieved. For simulation of the controllers MATLAB simulation software is used.","PeriodicalId":326163,"journal":{"name":"2022 International Conference on Intelligent Controller and Computing for Smart Power (ICICCSP)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-07-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Load Frequency Control of Multi Area Power System Using Meta-heuristic/Artificial Intelligence Techniques\",\"authors\":\"Junaid Hussain Lanker, Ravi Bhushan, Neeraj Gupta\",\"doi\":\"10.1109/ICICCSP53532.2022.9862473\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents multi area load frequency control (LFC) using artificial intelligence techniques in a power system comprising of non-reheat thermal power units for a three area interconnected power system. In this proposed scheme, fuzzy logic, Artificial Neural Network and Genetic Algorithm technique has been used to tune the classical PID controller for each area. Step load disturbance has been applied to assess its consequence on the dynamic performance of power system. The results are compared and appreciable change i.e minimum overshoot/undershoot, less settling time and a better response is achieved. For simulation of the controllers MATLAB simulation software is used.\",\"PeriodicalId\":326163,\"journal\":{\"name\":\"2022 International Conference on Intelligent Controller and Computing for Smart Power (ICICCSP)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-07-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 International Conference on Intelligent Controller and Computing for Smart Power (ICICCSP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICICCSP53532.2022.9862473\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Conference on Intelligent Controller and Computing for Smart Power (ICICCSP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICICCSP53532.2022.9862473","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

针对三区互联的非再热火电机组电力系统,提出了一种基于人工智能技术的多区负荷频率控制方法。该方案采用模糊逻辑、人工神经网络和遗传算法对各区域的经典PID控制器进行整定。应用阶跃负荷扰动来评估其对电力系统动态性能的影响。结果比较和明显的变化,即最小的超调/欠调,更少的稳定时间和更好的响应实现。采用MATLAB仿真软件对控制器进行仿真。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Load Frequency Control of Multi Area Power System Using Meta-heuristic/Artificial Intelligence Techniques
This paper presents multi area load frequency control (LFC) using artificial intelligence techniques in a power system comprising of non-reheat thermal power units for a three area interconnected power system. In this proposed scheme, fuzzy logic, Artificial Neural Network and Genetic Algorithm technique has been used to tune the classical PID controller for each area. Step load disturbance has been applied to assess its consequence on the dynamic performance of power system. The results are compared and appreciable change i.e minimum overshoot/undershoot, less settling time and a better response is achieved. For simulation of the controllers MATLAB simulation software is used.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信