{"title":"超弹性TiNi细丝的变形特征","authors":"E. Marchenko, G. Baigonakova, S. Gunther, O. Mamazakirov","doi":"10.31399/asm.cp.smst2022p0085","DOIUrl":null,"url":null,"abstract":"\n TiNi-based wire is widely used in the manufacture of surgical implants and designs due to its biocompatibility and ability to undergo viscoelastic deformation with tissues, withstanding millions of deformation cycles without destruction. TiNi is a self-passivating material, as it forms a complex surface oxide layer that protects the material from corrosion and is itself biocompatible. The functional properties of TiNi wire are determined by the structure, composition, and thickness. The purpose of this work is to study the deformation behavior of thin TiNi wires depending on the thickness. TiNi wires of different thicknesses (40, 60, 90 µm) were tested by uniaxial tension to rupture and in the load-unload cycle (5 cycles). The results found that All TiNi wires exhibit the effect of superelasticity at a relative strain of 5-7%. With an increase in the wire thickness from 40 to 90 µm, the values of the martensitic shear stress increase from 450 to 1200 MPa and the tensile strength increases from 1300 to 3150 MPa.","PeriodicalId":119283,"journal":{"name":"SMST 2022: Extended Abstracts from the International Conference on Shape Memory and Superelastic Technologies","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Features of Deformation of Thin Superelastic TiNi Wire\",\"authors\":\"E. Marchenko, G. Baigonakova, S. Gunther, O. Mamazakirov\",\"doi\":\"10.31399/asm.cp.smst2022p0085\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n TiNi-based wire is widely used in the manufacture of surgical implants and designs due to its biocompatibility and ability to undergo viscoelastic deformation with tissues, withstanding millions of deformation cycles without destruction. TiNi is a self-passivating material, as it forms a complex surface oxide layer that protects the material from corrosion and is itself biocompatible. The functional properties of TiNi wire are determined by the structure, composition, and thickness. The purpose of this work is to study the deformation behavior of thin TiNi wires depending on the thickness. TiNi wires of different thicknesses (40, 60, 90 µm) were tested by uniaxial tension to rupture and in the load-unload cycle (5 cycles). The results found that All TiNi wires exhibit the effect of superelasticity at a relative strain of 5-7%. With an increase in the wire thickness from 40 to 90 µm, the values of the martensitic shear stress increase from 450 to 1200 MPa and the tensile strength increases from 1300 to 3150 MPa.\",\"PeriodicalId\":119283,\"journal\":{\"name\":\"SMST 2022: Extended Abstracts from the International Conference on Shape Memory and Superelastic Technologies\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SMST 2022: Extended Abstracts from the International Conference on Shape Memory and Superelastic Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31399/asm.cp.smst2022p0085\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SMST 2022: Extended Abstracts from the International Conference on Shape Memory and Superelastic Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31399/asm.cp.smst2022p0085","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于其生物相容性和与组织进行粘弹性变形的能力,可以承受数百万次的变形循环而不受破坏,ti基金属丝被广泛用于外科植入物的制造和设计。TiNi是一种自钝化材料,因为它形成一个复杂的表面氧化层,保护材料免受腐蚀,并且本身具有生物相容性。TiNi丝的功能性能是由其结构、成分和厚度决定的。本工作的目的是研究TiNi细丝随厚度变化的变形行为。对40、60、90µm不同厚度的TiNi钢丝进行单轴拉伸断裂和5次加载-卸载循环试验。结果表明,在相对应变为5-7%时,所有TiNi钢丝均表现出超弹性效应。当线材厚度从40µm增加到90µm时,马氏体剪切应力值从450增大到1200 MPa,抗拉强度从1300增大到3150 MPa。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Features of Deformation of Thin Superelastic TiNi Wire
TiNi-based wire is widely used in the manufacture of surgical implants and designs due to its biocompatibility and ability to undergo viscoelastic deformation with tissues, withstanding millions of deformation cycles without destruction. TiNi is a self-passivating material, as it forms a complex surface oxide layer that protects the material from corrosion and is itself biocompatible. The functional properties of TiNi wire are determined by the structure, composition, and thickness. The purpose of this work is to study the deformation behavior of thin TiNi wires depending on the thickness. TiNi wires of different thicknesses (40, 60, 90 µm) were tested by uniaxial tension to rupture and in the load-unload cycle (5 cycles). The results found that All TiNi wires exhibit the effect of superelasticity at a relative strain of 5-7%. With an increase in the wire thickness from 40 to 90 µm, the values of the martensitic shear stress increase from 450 to 1200 MPa and the tensile strength increases from 1300 to 3150 MPa.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信