{"title":"用校正滤波器降低移动心电监测系统中生物阻抗对心电的影响","authors":"M. Safronov, A. Kuzmin, O. Bodin, V. Baranov, O. Timokhina, O. Cheban","doi":"10.23919/fruct49677.2020.9211026","DOIUrl":null,"url":null,"abstract":"The paper considers the problem of distortion of the ECG curve caused by bioimpedance of a patient’s skin. The authors compare traditional analytical methods of bioimpedance estimation based on equivalent circuits (RLC and others) and “black box” method. Advantage of “black box” method is shown in the task of estimation of parameters of parasitic filter of the skin in comparison with traditional methods. The paper describes the theoretical base and the measurement experiment directed to estimation of real transition parameters of the correction filter. Obtained digital correction filter was experimentally investigated. The results of the computational experiment with ECG records from PhysioNET base shows the impact of bioimpedance changes to ECG signal form. The proposed solution is intended to implementation in portable heart monitoring systems.","PeriodicalId":149674,"journal":{"name":"2020 27th Conference of Open Innovations Association (FRUCT)","volume":"73 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Reducing of Bioimpedance Influence on ECG by Correction Filter in Mobile Heart Monitoring System\",\"authors\":\"M. Safronov, A. Kuzmin, O. Bodin, V. Baranov, O. Timokhina, O. Cheban\",\"doi\":\"10.23919/fruct49677.2020.9211026\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper considers the problem of distortion of the ECG curve caused by bioimpedance of a patient’s skin. The authors compare traditional analytical methods of bioimpedance estimation based on equivalent circuits (RLC and others) and “black box” method. Advantage of “black box” method is shown in the task of estimation of parameters of parasitic filter of the skin in comparison with traditional methods. The paper describes the theoretical base and the measurement experiment directed to estimation of real transition parameters of the correction filter. Obtained digital correction filter was experimentally investigated. The results of the computational experiment with ECG records from PhysioNET base shows the impact of bioimpedance changes to ECG signal form. The proposed solution is intended to implementation in portable heart monitoring systems.\",\"PeriodicalId\":149674,\"journal\":{\"name\":\"2020 27th Conference of Open Innovations Association (FRUCT)\",\"volume\":\"73 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 27th Conference of Open Innovations Association (FRUCT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/fruct49677.2020.9211026\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 27th Conference of Open Innovations Association (FRUCT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/fruct49677.2020.9211026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Reducing of Bioimpedance Influence on ECG by Correction Filter in Mobile Heart Monitoring System
The paper considers the problem of distortion of the ECG curve caused by bioimpedance of a patient’s skin. The authors compare traditional analytical methods of bioimpedance estimation based on equivalent circuits (RLC and others) and “black box” method. Advantage of “black box” method is shown in the task of estimation of parameters of parasitic filter of the skin in comparison with traditional methods. The paper describes the theoretical base and the measurement experiment directed to estimation of real transition parameters of the correction filter. Obtained digital correction filter was experimentally investigated. The results of the computational experiment with ECG records from PhysioNET base shows the impact of bioimpedance changes to ECG signal form. The proposed solution is intended to implementation in portable heart monitoring systems.