LLS性能分析:不同中央处理器的比较

C. Mesquita, R. Dias, S. Visacro, G. M. M. Paixao
{"title":"LLS性能分析:不同中央处理器的比较","authors":"C. Mesquita, R. Dias, S. Visacro, G. M. M. Paixao","doi":"10.1109/SIPDA.2013.6729195","DOIUrl":null,"url":null,"abstract":"Lightning Location Systems (LLS) data are important source to characterize lightning incidence considering extensive regions and allowing different analysis related to power system performance and protection actions against lightning incidence on transmission lines and distribution routes. After a recent upgrade of LLS central processor in Minas Gerais State, a performance analysis was done. The authors analyzed the improvements on location accuracy and peak current estimate of the LLS central processor. In order to perform it, two different reprocessing were done using the same database of sensor reports. So a comparison between lightning location data obtained by using of two different central processors is presented. Also lightning currents directly measured at Morro do Cachimbo Station (MCS) was used as reference data.","PeriodicalId":216871,"journal":{"name":"2013 International Symposium on Lightning Protection (XII SIPDA)","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of LLS performance: Comparison of different central processors\",\"authors\":\"C. Mesquita, R. Dias, S. Visacro, G. M. M. Paixao\",\"doi\":\"10.1109/SIPDA.2013.6729195\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Lightning Location Systems (LLS) data are important source to characterize lightning incidence considering extensive regions and allowing different analysis related to power system performance and protection actions against lightning incidence on transmission lines and distribution routes. After a recent upgrade of LLS central processor in Minas Gerais State, a performance analysis was done. The authors analyzed the improvements on location accuracy and peak current estimate of the LLS central processor. In order to perform it, two different reprocessing were done using the same database of sensor reports. So a comparison between lightning location data obtained by using of two different central processors is presented. Also lightning currents directly measured at Morro do Cachimbo Station (MCS) was used as reference data.\",\"PeriodicalId\":216871,\"journal\":{\"name\":\"2013 International Symposium on Lightning Protection (XII SIPDA)\",\"volume\":\"57 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 International Symposium on Lightning Protection (XII SIPDA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIPDA.2013.6729195\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 International Symposium on Lightning Protection (XII SIPDA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIPDA.2013.6729195","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

雷电定位系统(LLS)数据是表征雷击发生率的重要来源,考虑到广泛的区域,允许对电力系统性能和输电线路和配电线路上的雷击防护措施进行不同的分析。在米纳斯吉拉斯州最近升级了LLS中央处理器后,进行了性能分析。分析了LLS中央处理器在定位精度和峰值电流估计方面的改进。为了实现它,使用相同的传感器报告数据库进行了两次不同的再处理。在此基础上,对使用两种不同中央处理器获得的闪电定位数据进行了比较。并以Morro do Cachimbo站(MCS)直接测得的雷电流作为参考资料。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis of LLS performance: Comparison of different central processors
Lightning Location Systems (LLS) data are important source to characterize lightning incidence considering extensive regions and allowing different analysis related to power system performance and protection actions against lightning incidence on transmission lines and distribution routes. After a recent upgrade of LLS central processor in Minas Gerais State, a performance analysis was done. The authors analyzed the improvements on location accuracy and peak current estimate of the LLS central processor. In order to perform it, two different reprocessing were done using the same database of sensor reports. So a comparison between lightning location data obtained by using of two different central processors is presented. Also lightning currents directly measured at Morro do Cachimbo Station (MCS) was used as reference data.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信