{"title":"非均匀电场作用下氩+SF/sub - 6/混合物放电起始电压的计算","authors":"R. Hiziroglu, M. Dincer","doi":"10.1109/CEIDP.2000.885316","DOIUrl":null,"url":null,"abstract":"In this study discharge inception voltages in Ar+SF/sub 6/ binary mixtures are calculated based on the streamer criterion under nonuniform electrostatic fields. The calculations are done for different contents of SF/sub 6/ in the mixture and the total gas pressure is varied as a parameter from 50 kPa to 100 kPa. The computed discharge inception voltages using the streamer criterion are found to be in good agreement with the experimental data.","PeriodicalId":414762,"journal":{"name":"2000 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.00CH37132)","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Calculation of discharge inception voltages in argon+SF/sub 6/ mixtures under nonuniform electric fields\",\"authors\":\"R. Hiziroglu, M. Dincer\",\"doi\":\"10.1109/CEIDP.2000.885316\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study discharge inception voltages in Ar+SF/sub 6/ binary mixtures are calculated based on the streamer criterion under nonuniform electrostatic fields. The calculations are done for different contents of SF/sub 6/ in the mixture and the total gas pressure is varied as a parameter from 50 kPa to 100 kPa. The computed discharge inception voltages using the streamer criterion are found to be in good agreement with the experimental data.\",\"PeriodicalId\":414762,\"journal\":{\"name\":\"2000 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.00CH37132)\",\"volume\":\"60 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2000 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.00CH37132)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2000.885316\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2000 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.00CH37132)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2000.885316","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Calculation of discharge inception voltages in argon+SF/sub 6/ mixtures under nonuniform electric fields
In this study discharge inception voltages in Ar+SF/sub 6/ binary mixtures are calculated based on the streamer criterion under nonuniform electrostatic fields. The calculations are done for different contents of SF/sub 6/ in the mixture and the total gas pressure is varied as a parameter from 50 kPa to 100 kPa. The computed discharge inception voltages using the streamer criterion are found to be in good agreement with the experimental data.