{"title":"夹紧接头系统的诊断","authors":"M. Musil, J. Úradníček, Marek Páleník, O. Chlebo","doi":"10.2478/scjme-2022-0022","DOIUrl":null,"url":null,"abstract":"Abstract The article describes a diagnostic method, on the basis of which it is possible to assess whether there is a loose connection in the clamping system (detection) and to determine which of them is loose (localization). The diagnostic method is based on comparing the drops in the natural frequencies of a measured system with respect to a reference system, which simulates the desired state. When analysing the drop in natural frequencies in order to locate the loosening, it is necessary to relate this drop to the position of the clamping joints within the considered mode shape.","PeriodicalId":445896,"journal":{"name":"Strojnícky časopis - Journal of Mechanical Engineering","volume":"66 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Diagnostics of a Clamping Joint System\",\"authors\":\"M. Musil, J. Úradníček, Marek Páleník, O. Chlebo\",\"doi\":\"10.2478/scjme-2022-0022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The article describes a diagnostic method, on the basis of which it is possible to assess whether there is a loose connection in the clamping system (detection) and to determine which of them is loose (localization). The diagnostic method is based on comparing the drops in the natural frequencies of a measured system with respect to a reference system, which simulates the desired state. When analysing the drop in natural frequencies in order to locate the loosening, it is necessary to relate this drop to the position of the clamping joints within the considered mode shape.\",\"PeriodicalId\":445896,\"journal\":{\"name\":\"Strojnícky časopis - Journal of Mechanical Engineering\",\"volume\":\"66 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Strojnícky časopis - Journal of Mechanical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/scjme-2022-0022\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Strojnícky časopis - Journal of Mechanical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/scjme-2022-0022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Abstract The article describes a diagnostic method, on the basis of which it is possible to assess whether there is a loose connection in the clamping system (detection) and to determine which of them is loose (localization). The diagnostic method is based on comparing the drops in the natural frequencies of a measured system with respect to a reference system, which simulates the desired state. When analysing the drop in natural frequencies in order to locate the loosening, it is necessary to relate this drop to the position of the clamping joints within the considered mode shape.