Yuze Jiang, Lefeng Li, Diwen Jiang, Zhenguang Liang, Fangwei Li
{"title":"带屏蔽导体的高压直流架空输电线路的电场","authors":"Yuze Jiang, Lefeng Li, Diwen Jiang, Zhenguang Liang, Fangwei Li","doi":"10.1109/AEEES51875.2021.9403161","DOIUrl":null,"url":null,"abstract":"High voltage direct current (HVDC) overhead transmission lines produce ion flow and space charge which lead to serious contamination than that of high voltage alternating current (HVAC). Corona and contamination of HVDC may be restrained by covering conductors with insulation layer. In the paper, model of HVDC overhead transmission lines with covered conductors is presented. Electric field is calculated. Results show that covered conductors can restrain ion flow field obviously.","PeriodicalId":356667,"journal":{"name":"2021 3rd Asia Energy and Electrical Engineering Symposium (AEEES)","volume":"13 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electric Field of High Voltage Direct Current Overhead Transmission Lines with Covered Conductors\",\"authors\":\"Yuze Jiang, Lefeng Li, Diwen Jiang, Zhenguang Liang, Fangwei Li\",\"doi\":\"10.1109/AEEES51875.2021.9403161\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High voltage direct current (HVDC) overhead transmission lines produce ion flow and space charge which lead to serious contamination than that of high voltage alternating current (HVAC). Corona and contamination of HVDC may be restrained by covering conductors with insulation layer. In the paper, model of HVDC overhead transmission lines with covered conductors is presented. Electric field is calculated. Results show that covered conductors can restrain ion flow field obviously.\",\"PeriodicalId\":356667,\"journal\":{\"name\":\"2021 3rd Asia Energy and Electrical Engineering Symposium (AEEES)\",\"volume\":\"13 2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-03-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 3rd Asia Energy and Electrical Engineering Symposium (AEEES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AEEES51875.2021.9403161\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 3rd Asia Energy and Electrical Engineering Symposium (AEEES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AEEES51875.2021.9403161","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Electric Field of High Voltage Direct Current Overhead Transmission Lines with Covered Conductors
High voltage direct current (HVDC) overhead transmission lines produce ion flow and space charge which lead to serious contamination than that of high voltage alternating current (HVAC). Corona and contamination of HVDC may be restrained by covering conductors with insulation layer. In the paper, model of HVDC overhead transmission lines with covered conductors is presented. Electric field is calculated. Results show that covered conductors can restrain ion flow field obviously.