利用android手机测量变电站负载电流

N. Strickland, D. Strickland, B. Goss, A. Cross, D. Thompson, M. Thomson, R. Ferris, M. Watson
{"title":"利用android手机测量变电站负载电流","authors":"N. Strickland, D. Strickland, B. Goss, A. Cross, D. Thompson, M. Thomson, R. Ferris, M. Watson","doi":"10.1049/icp.2021.0958","DOIUrl":null,"url":null,"abstract":"To enable the full range of “smart” grid functionality at all levels of the distribution and transmission network it is necessary to have a widespread roll out of measurement of loading. At present, traditional devices are too expensive to install across all 11kV/400V substations. This paper details an approach using the sensors in a typical android mobile phone to detect and measure load current at a cost significantly lower than traditional measurements. The paper covers the theory behind how such an implementation could be undertaken and presents results based on testing in a substation on single phase and three phase cable. The data is manipulated on the phone and then uploaded to a server. Results are encouraging but significant follow on work is needed.","PeriodicalId":188371,"journal":{"name":"The 10th International Conference on Power Electronics, Machines and Drives (PEMD 2020)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"MEASUREMENT OF SUBSTATION LOAD CURRENT USING AN ANDROID PHONE\",\"authors\":\"N. Strickland, D. Strickland, B. Goss, A. Cross, D. Thompson, M. Thomson, R. Ferris, M. Watson\",\"doi\":\"10.1049/icp.2021.0958\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To enable the full range of “smart” grid functionality at all levels of the distribution and transmission network it is necessary to have a widespread roll out of measurement of loading. At present, traditional devices are too expensive to install across all 11kV/400V substations. This paper details an approach using the sensors in a typical android mobile phone to detect and measure load current at a cost significantly lower than traditional measurements. The paper covers the theory behind how such an implementation could be undertaken and presents results based on testing in a substation on single phase and three phase cable. The data is manipulated on the phone and then uploaded to a server. Results are encouraging but significant follow on work is needed.\",\"PeriodicalId\":188371,\"journal\":{\"name\":\"The 10th International Conference on Power Electronics, Machines and Drives (PEMD 2020)\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The 10th International Conference on Power Electronics, Machines and Drives (PEMD 2020)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1049/icp.2021.0958\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 10th International Conference on Power Electronics, Machines and Drives (PEMD 2020)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/icp.2021.0958","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了在各级配电和输电网络中实现全面的“智能”电网功能,有必要广泛推出负载测量。目前,传统设备过于昂贵,无法在所有11kV/400V变电站安装。本文详细介绍了一种利用典型android手机中的传感器来检测和测量负载电流的方法,其成本大大低于传统的测量方法。本文涵盖了如何实施这种方法的理论,并介绍了基于变电站单相和三相电缆测试的结果。这些数据在手机上被处理,然后上传到服务器上。结果令人鼓舞,但需要大量的后续工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
MEASUREMENT OF SUBSTATION LOAD CURRENT USING AN ANDROID PHONE
To enable the full range of “smart” grid functionality at all levels of the distribution and transmission network it is necessary to have a widespread roll out of measurement of loading. At present, traditional devices are too expensive to install across all 11kV/400V substations. This paper details an approach using the sensors in a typical android mobile phone to detect and measure load current at a cost significantly lower than traditional measurements. The paper covers the theory behind how such an implementation could be undertaken and presents results based on testing in a substation on single phase and three phase cable. The data is manipulated on the phone and then uploaded to a server. Results are encouraging but significant follow on work is needed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信