W. Marynowski, A. Kusiek, J. Mazur
{"title":"微带FCL切片隔离器的研究","authors":"W. Marynowski, A. Kusiek, J. Mazur","doi":"10.1109/RADIOELEK.2007.371690","DOIUrl":null,"url":null,"abstract":"This paper describes the design of the isolator containing longitudinally magnetized microstrip ferrite coupled lines (FCL). In the sandwich structure of circuit the ferrite slab was introduced as an overlay. The termination in the isolator circuit was realized in two different ways: as a coaxial load and as a planar microstrip structure with lumped resistor. The results of the simulation were experimentally verified. Between simulations and measurements a good agreement was achieved. Better results was obtained for isolator with the coaxial load. The experiment showed average transmission losses better than -2dB in the band from 10.4 to 15GHz. The average isolation was better than -15dB. The reflection losses in one port were better than in the other one (below -15dB and average -12dB).","PeriodicalId":446406,"journal":{"name":"2007 17th International Conference Radioelektronika","volume":"86 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Investigations of the Isolators Containing Microstrip FCL Section\",\"authors\":\"W. Marynowski, A. Kusiek, J. Mazur\",\"doi\":\"10.1109/RADIOELEK.2007.371690\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes the design of the isolator containing longitudinally magnetized microstrip ferrite coupled lines (FCL). In the sandwich structure of circuit the ferrite slab was introduced as an overlay. The termination in the isolator circuit was realized in two different ways: as a coaxial load and as a planar microstrip structure with lumped resistor. The results of the simulation were experimentally verified. Between simulations and measurements a good agreement was achieved. Better results was obtained for isolator with the coaxial load. The experiment showed average transmission losses better than -2dB in the band from 10.4 to 15GHz. The average isolation was better than -15dB. The reflection losses in one port were better than in the other one (below -15dB and average -12dB).\",\"PeriodicalId\":446406,\"journal\":{\"name\":\"2007 17th International Conference Radioelektronika\",\"volume\":\"86 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-04-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 17th International Conference Radioelektronika\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/RADIOELEK.2007.371690\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 17th International Conference Radioelektronika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RADIOELEK.2007.371690","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文介绍了含纵向磁化微带铁氧体耦合线的隔离器的设计。在电路夹层结构中引入铁氧体板作为覆盖层。隔离电路的端接有两种不同的实现方式:同轴负载端接和带集总电阻的平面微带结构端接。仿真结果得到了实验验证。仿真结果与实测结果吻合较好。同轴负载下的隔离器效果较好。实验表明,在10.4 ~ 15GHz频段,平均传输损耗优于-2dB。平均隔离度优于-15dB。其中一个端口的反射损耗优于另一个端口(低于-15dB,平均为-12dB)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigations of the Isolators Containing Microstrip FCL Section
This paper describes the design of the isolator containing longitudinally magnetized microstrip ferrite coupled lines (FCL). In the sandwich structure of circuit the ferrite slab was introduced as an overlay. The termination in the isolator circuit was realized in two different ways: as a coaxial load and as a planar microstrip structure with lumped resistor. The results of the simulation were experimentally verified. Between simulations and measurements a good agreement was achieved. Better results was obtained for isolator with the coaxial load. The experiment showed average transmission losses better than -2dB in the band from 10.4 to 15GHz. The average isolation was better than -15dB. The reflection losses in one port were better than in the other one (below -15dB and average -12dB).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信