自动生成控制(AGC)模糊控制器的设计与体会

G. Chown, R. Hartman
{"title":"自动生成控制(AGC)模糊控制器的设计与体会","authors":"G. Chown, R. Hartman","doi":"10.1109/PICA.1997.599425","DOIUrl":null,"url":null,"abstract":"This paper describes the design, implementation and operational performance of a fuzzy controller as part of the automatic generation control (AGC) system in Eskom's National Control Centre. The fuzzy controller was implemented in the area control error calculation, which determines the shortfall or surplus generation that has to be corrected. This paper sets out the problems associated with secondary frequency control and AGC. The difficulties associated with optimising the original standard AGC controller, the design, implementation and optimisation of the fuzzy controller and the operational performance of the new controller over two years, are discussed. The fuzzy controller was integrated into the existing off-the-shelf AGC system with only a few modifications. The operational performance over two years showed an overall improvement of over 50% in the reduction of control compared to the original AGC controller, and an initial improvement of 20% in the quality of control of the optimised original controller.","PeriodicalId":383749,"journal":{"name":"Proceedings of the 20th International Conference on Power Industry Computer Applications","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"178","resultStr":"{\"title\":\"Design and experience with a fuzzy logic controller for automatic generation control (AGC)\",\"authors\":\"G. Chown, R. Hartman\",\"doi\":\"10.1109/PICA.1997.599425\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes the design, implementation and operational performance of a fuzzy controller as part of the automatic generation control (AGC) system in Eskom's National Control Centre. The fuzzy controller was implemented in the area control error calculation, which determines the shortfall or surplus generation that has to be corrected. This paper sets out the problems associated with secondary frequency control and AGC. The difficulties associated with optimising the original standard AGC controller, the design, implementation and optimisation of the fuzzy controller and the operational performance of the new controller over two years, are discussed. The fuzzy controller was integrated into the existing off-the-shelf AGC system with only a few modifications. The operational performance over two years showed an overall improvement of over 50% in the reduction of control compared to the original AGC controller, and an initial improvement of 20% in the quality of control of the optimised original controller.\",\"PeriodicalId\":383749,\"journal\":{\"name\":\"Proceedings of the 20th International Conference on Power Industry Computer Applications\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-05-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"178\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 20th International Conference on Power Industry Computer Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PICA.1997.599425\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 20th International Conference on Power Industry Computer Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PICA.1997.599425","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 178

摘要

本文介绍了作为Eskom国家控制中心自动发电控制(AGC)系统一部分的模糊控制器的设计、实现和运行性能。在区域控制误差计算中引入模糊控制器,确定需要修正的不足或剩余发电量。本文阐述了二次频率控制与AGC的相关问题。讨论了优化原始标准AGC控制器的困难,模糊控制器的设计,实现和优化以及新控制器在两年内的运行性能。该模糊控制器仅经过少量修改就集成到现有的现成AGC系统中。两年多的运行性能表明,与原始AGC控制器相比,控制减少的总体改善超过50%,优化后的原始控制器的控制质量初步改善了20%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design and experience with a fuzzy logic controller for automatic generation control (AGC)
This paper describes the design, implementation and operational performance of a fuzzy controller as part of the automatic generation control (AGC) system in Eskom's National Control Centre. The fuzzy controller was implemented in the area control error calculation, which determines the shortfall or surplus generation that has to be corrected. This paper sets out the problems associated with secondary frequency control and AGC. The difficulties associated with optimising the original standard AGC controller, the design, implementation and optimisation of the fuzzy controller and the operational performance of the new controller over two years, are discussed. The fuzzy controller was integrated into the existing off-the-shelf AGC system with only a few modifications. The operational performance over two years showed an overall improvement of over 50% in the reduction of control compared to the original AGC controller, and an initial improvement of 20% in the quality of control of the optimised original controller.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信