Paul C.-P. Paul, Pei-Yu Chiang, D. Tarng, Chih-Yu Yang
{"title":"应用新型光容积脉搏波传感器测量血液透析(HD)患者动静脉瘘(AVF)血流量(BFV)的数学推导、电路设计及临床实验","authors":"Paul C.-P. Paul, Pei-Yu Chiang, D. Tarng, Chih-Yu Yang","doi":"10.1109/ISQED.2018.8357312","DOIUrl":null,"url":null,"abstract":"Mathematical derivation of calculating blood flow volume (BFV) at arteriovenous fistula (AVF) using a newly-developed photoplethysmography (PPG) sensor is presented in this work. Also, the readout circuit of the PPG sensor intended to increase the signal-noise ratio (S/NR) is designed and presented in this work. The designed PPG sensor equipped with derived mathematical equations shows high correlation (R2 = 0.7563) and low error (RMSE = 212 ml/min) as compared to the gold standard.","PeriodicalId":213351,"journal":{"name":"2018 19th International Symposium on Quality Electronic Design (ISQED)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Mathematical derivation, circuits design and clinical experiments of measuring blood flow volume (BFV) at arteriovenous fistula (AVF) of hemodialysis (HD) patients using a newly-developed photoplethysmography (PPG) sensor\",\"authors\":\"Paul C.-P. Paul, Pei-Yu Chiang, D. Tarng, Chih-Yu Yang\",\"doi\":\"10.1109/ISQED.2018.8357312\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Mathematical derivation of calculating blood flow volume (BFV) at arteriovenous fistula (AVF) using a newly-developed photoplethysmography (PPG) sensor is presented in this work. Also, the readout circuit of the PPG sensor intended to increase the signal-noise ratio (S/NR) is designed and presented in this work. The designed PPG sensor equipped with derived mathematical equations shows high correlation (R2 = 0.7563) and low error (RMSE = 212 ml/min) as compared to the gold standard.\",\"PeriodicalId\":213351,\"journal\":{\"name\":\"2018 19th International Symposium on Quality Electronic Design (ISQED)\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 19th International Symposium on Quality Electronic Design (ISQED)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISQED.2018.8357312\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 19th International Symposium on Quality Electronic Design (ISQED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISQED.2018.8357312","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Mathematical derivation, circuits design and clinical experiments of measuring blood flow volume (BFV) at arteriovenous fistula (AVF) of hemodialysis (HD) patients using a newly-developed photoplethysmography (PPG) sensor
Mathematical derivation of calculating blood flow volume (BFV) at arteriovenous fistula (AVF) using a newly-developed photoplethysmography (PPG) sensor is presented in this work. Also, the readout circuit of the PPG sensor intended to increase the signal-noise ratio (S/NR) is designed and presented in this work. The designed PPG sensor equipped with derived mathematical equations shows high correlation (R2 = 0.7563) and low error (RMSE = 212 ml/min) as compared to the gold standard.