Seyed Javad Mirazimiabarghouei, T. Ahfock, A. Helwig
{"title":"单线接地返回(SWER)系统电压支持使用四象限DSTATCOM","authors":"Seyed Javad Mirazimiabarghouei, T. Ahfock, A. Helwig","doi":"10.1109/PECON.2016.7951564","DOIUrl":null,"url":null,"abstract":"Single Wire Earth Return (SWER) systems with long transmission line were introduced as one of the low cost options for remote electrification. Long transmission lines and load growth in such a system make voltage regulation a concern. Four quadrants distribution STATic COMpensators (DSTATCOMs) as voltage support equipment in SWER system with ability of injecting or absorbing active and reactive power is proposed. In this paper, the operation of DSTATCOMs in terms of voltage support effectiveness is studied. Particularly, the focus is on DSTATCOM Optimum Operation Point (DOOP) to have the maximum possible support during heavy load. A SWER system is developed, using MATLAB, to study the effect of DSTATCOM operation point on the system voltage profile.","PeriodicalId":259969,"journal":{"name":"2016 IEEE International Conference on Power and Energy (PECon)","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Single Wire Earth Return (SWER) system voltage support using four quadrant DSTATCOM\",\"authors\":\"Seyed Javad Mirazimiabarghouei, T. Ahfock, A. Helwig\",\"doi\":\"10.1109/PECON.2016.7951564\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Single Wire Earth Return (SWER) systems with long transmission line were introduced as one of the low cost options for remote electrification. Long transmission lines and load growth in such a system make voltage regulation a concern. Four quadrants distribution STATic COMpensators (DSTATCOMs) as voltage support equipment in SWER system with ability of injecting or absorbing active and reactive power is proposed. In this paper, the operation of DSTATCOMs in terms of voltage support effectiveness is studied. Particularly, the focus is on DSTATCOM Optimum Operation Point (DOOP) to have the maximum possible support during heavy load. A SWER system is developed, using MATLAB, to study the effect of DSTATCOM operation point on the system voltage profile.\",\"PeriodicalId\":259969,\"journal\":{\"name\":\"2016 IEEE International Conference on Power and Energy (PECon)\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE International Conference on Power and Energy (PECon)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PECON.2016.7951564\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Conference on Power and Energy (PECon)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECON.2016.7951564","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Single Wire Earth Return (SWER) system voltage support using four quadrant DSTATCOM
Single Wire Earth Return (SWER) systems with long transmission line were introduced as one of the low cost options for remote electrification. Long transmission lines and load growth in such a system make voltage regulation a concern. Four quadrants distribution STATic COMpensators (DSTATCOMs) as voltage support equipment in SWER system with ability of injecting or absorbing active and reactive power is proposed. In this paper, the operation of DSTATCOMs in terms of voltage support effectiveness is studied. Particularly, the focus is on DSTATCOM Optimum Operation Point (DOOP) to have the maximum possible support during heavy load. A SWER system is developed, using MATLAB, to study the effect of DSTATCOM operation point on the system voltage profile.