S. Motoasca
{"title":"软磁材料功率损耗频率依赖性的LabVIEW建模","authors":"S. Motoasca","doi":"10.1109/OPTIM.2012.6231938","DOIUrl":null,"url":null,"abstract":"The paper deal with Steinmetz power losses equation developed in LabVIEW program. The initial equation is used after the area of hysteresis cycle is calculated using the LabVIEW VI's. It is important to have enough points considered on the major hysteresis loop to obtain with good accuracy the power losses. For this reason we use some VI's to interpolate the space between measurement data to have more datas. In this paper we made only the frequency dependence of the power losses and in the future we plan to go to the time domain. We try also to made the power losses separation between hysteresis losses and other losses taking for the DC case the frequency f=0,05 corresponding to IEC 60404 which specifies that for one major cycle is enough to be obtained in 20 seconds.","PeriodicalId":382406,"journal":{"name":"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)","volume":"79 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"LabVIEW modeling of frequency dependence of power losses in soft magnetic materials\",\"authors\":\"S. Motoasca\",\"doi\":\"10.1109/OPTIM.2012.6231938\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper deal with Steinmetz power losses equation developed in LabVIEW program. The initial equation is used after the area of hysteresis cycle is calculated using the LabVIEW VI's. It is important to have enough points considered on the major hysteresis loop to obtain with good accuracy the power losses. For this reason we use some VI's to interpolate the space between measurement data to have more datas. In this paper we made only the frequency dependence of the power losses and in the future we plan to go to the time domain. We try also to made the power losses separation between hysteresis losses and other losses taking for the DC case the frequency f=0,05 corresponding to IEC 60404 which specifies that for one major cycle is enough to be obtained in 20 seconds.\",\"PeriodicalId\":382406,\"journal\":{\"name\":\"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)\",\"volume\":\"79 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/OPTIM.2012.6231938\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OPTIM.2012.6231938","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文讨论了在LabVIEW程序中建立的Steinmetz功率损耗方程。利用LabVIEW VI's计算迟滞周期面积后,使用初始方程。重要的是要在主磁滞回线上考虑足够多的点,以便准确地获得功率损耗。出于这个原因,我们使用一些VI来插入测量数据之间的空间以获得更多的数据。在本文中,我们只考虑了功率损耗的频率依赖性,未来我们计划进入时域。我们还尝试使功率损耗在迟滞损耗和其他损耗之间分离,对于直流情况,频率f= 0.05对应于IEC 60404,其中规定一个主要周期足以在20秒内获得。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
LabVIEW modeling of frequency dependence of power losses in soft magnetic materials
The paper deal with Steinmetz power losses equation developed in LabVIEW program. The initial equation is used after the area of hysteresis cycle is calculated using the LabVIEW VI's. It is important to have enough points considered on the major hysteresis loop to obtain with good accuracy the power losses. For this reason we use some VI's to interpolate the space between measurement data to have more datas. In this paper we made only the frequency dependence of the power losses and in the future we plan to go to the time domain. We try also to made the power losses separation between hysteresis losses and other losses taking for the DC case the frequency f=0,05 corresponding to IEC 60404 which specifies that for one major cycle is enough to be obtained in 20 seconds.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信