提出了一种结合SMS和Q-f的混合孤岛检测方法,用于逆变器DG的孤岛检测

S. Akhlaghi, A. Ghadimi, A. Akhlaghi
{"title":"提出了一种结合SMS和Q-f的混合孤岛检测方法,用于逆变器DG的孤岛检测","authors":"S. Akhlaghi, A. Ghadimi, A. Akhlaghi","doi":"10.1109/PECI.2014.6804571","DOIUrl":null,"url":null,"abstract":"In this paper a novel hybrid method for islanding detection of inverter- based distributed generation is proposed. This algorithm which is a combination of Slip mode frequency-shift (SMS) and reactive power versus frequency (Q-f) as active methods detects the islanding phenomena by forcing the DG lose its stable operation and drift the frequency out of the allowed normal range of the frequency relays. A simple passive islanding detection scheme that relies on frequency relays such as under/over frequency protection (UFP/OFP) would be sufficient to detect the moment of islanding. For demonstrating the performance of the proposed method, it is evaluated under the IEEE 1547, UL 1741 anti-islanding test configuration and multiple-DG operation. The studies reported in this paper are based on time-domain simulations in the MATLAB/Simulink. The proposed hybrid method detects islanding more efficiently for loads with high quality factor (Qf); also it operates accurately in condition of load switching and does not interfere with the power system operation during normal conditions. Simulation results prove that the proposed method decreases the time of islanding detection and has less Non Detection Zone in comparison to previous methods. In addition, the technique represents to be robust under multiple-DG operations.","PeriodicalId":352005,"journal":{"name":"2014 Power and Energy Conference at Illinois (PECI)","volume":"97 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"40","resultStr":"{\"title\":\"A novel hybrid islanding detection method combination of SMS and Q-f for islanding detection of inverter- based DG\",\"authors\":\"S. Akhlaghi, A. Ghadimi, A. Akhlaghi\",\"doi\":\"10.1109/PECI.2014.6804571\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper a novel hybrid method for islanding detection of inverter- based distributed generation is proposed. This algorithm which is a combination of Slip mode frequency-shift (SMS) and reactive power versus frequency (Q-f) as active methods detects the islanding phenomena by forcing the DG lose its stable operation and drift the frequency out of the allowed normal range of the frequency relays. A simple passive islanding detection scheme that relies on frequency relays such as under/over frequency protection (UFP/OFP) would be sufficient to detect the moment of islanding. For demonstrating the performance of the proposed method, it is evaluated under the IEEE 1547, UL 1741 anti-islanding test configuration and multiple-DG operation. The studies reported in this paper are based on time-domain simulations in the MATLAB/Simulink. The proposed hybrid method detects islanding more efficiently for loads with high quality factor (Qf); also it operates accurately in condition of load switching and does not interfere with the power system operation during normal conditions. Simulation results prove that the proposed method decreases the time of islanding detection and has less Non Detection Zone in comparison to previous methods. In addition, the technique represents to be robust under multiple-DG operations.\",\"PeriodicalId\":352005,\"journal\":{\"name\":\"2014 Power and Energy Conference at Illinois (PECI)\",\"volume\":\"97 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-04-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"40\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 Power and Energy Conference at Illinois (PECI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PECI.2014.6804571\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 Power and Energy Conference at Illinois (PECI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECI.2014.6804571","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 40

摘要

本文提出了一种新的基于逆变器的分布式发电孤岛检测混合方法。该算法结合了滑移模频移(SMS)和无功功率对频率(Q-f)作为主动方法,通过迫使DG失去稳定运行并将频率漂移到频率继电器允许的正常范围之外来检测孤岛现象。一个简单的无源孤岛检测方案,依赖于频率继电器,如频率过低/过频保护(UFP/OFP),将足以检测孤岛时刻。为了验证该方法的性能,在IEEE 1547、UL 1741抗孤岛测试配置和多dg操作下对其进行了评估。本文的研究是基于MATLAB/Simulink的时域仿真。该方法对高质量因子(Qf)负载的孤岛检测效率更高;在负荷切换情况下准确工作,不干扰电力系统正常运行。仿真结果表明,与现有方法相比,该方法缩短了孤岛检测时间,减少了非检测区域。此外,该技术在多dg操作下具有鲁棒性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A novel hybrid islanding detection method combination of SMS and Q-f for islanding detection of inverter- based DG
In this paper a novel hybrid method for islanding detection of inverter- based distributed generation is proposed. This algorithm which is a combination of Slip mode frequency-shift (SMS) and reactive power versus frequency (Q-f) as active methods detects the islanding phenomena by forcing the DG lose its stable operation and drift the frequency out of the allowed normal range of the frequency relays. A simple passive islanding detection scheme that relies on frequency relays such as under/over frequency protection (UFP/OFP) would be sufficient to detect the moment of islanding. For demonstrating the performance of the proposed method, it is evaluated under the IEEE 1547, UL 1741 anti-islanding test configuration and multiple-DG operation. The studies reported in this paper are based on time-domain simulations in the MATLAB/Simulink. The proposed hybrid method detects islanding more efficiently for loads with high quality factor (Qf); also it operates accurately in condition of load switching and does not interfere with the power system operation during normal conditions. Simulation results prove that the proposed method decreases the time of islanding detection and has less Non Detection Zone in comparison to previous methods. In addition, the technique represents to be robust under multiple-DG operations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信