Lee Holland, H. Karayaka, Martin L. Tanaka, Aaron Ball
{"title":"智能电网电阻加热器参数化负荷均衡控制方法研究","authors":"Lee Holland, H. Karayaka, Martin L. Tanaka, Aaron Ball","doi":"10.1109/GREENTECH.2014.15","DOIUrl":null,"url":null,"abstract":"The main goal in this study is to demonstrate that load levelling with demand side management in smart grids can be achieved to reduce peak power consumption while maintaining residential room temperatures at a comfortable level. A prototype enclosure was built and equipped with a heater and thermal measuring equipment. Data was collected during a 17 hour temperature regulation experiment using a traditional on-off (bang-bang) controller similar to those commonly used for residential heating control. A second order mathematical model was utilized to estimate the net thermal resistances and capacitances using system identification techniques at two different temperature set points. The enclosure system was used to determine if peak power could be reduced by slowly varying loads utilizing a different type of controller. Two different linear control techniques (using K-Factor and PI approaches) and the associated power electronics circuitry were implemented and tuned. Both controller systems successfully leveled the load and reduced the peak power demand.","PeriodicalId":194092,"journal":{"name":"2014 Sixth Annual IEEE Green Technologies Conference","volume":"276 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"An Investigation of Parametric Load Leveling Control Methodologies for Resistive Heaters in Smart Grids\",\"authors\":\"Lee Holland, H. Karayaka, Martin L. Tanaka, Aaron Ball\",\"doi\":\"10.1109/GREENTECH.2014.15\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The main goal in this study is to demonstrate that load levelling with demand side management in smart grids can be achieved to reduce peak power consumption while maintaining residential room temperatures at a comfortable level. A prototype enclosure was built and equipped with a heater and thermal measuring equipment. Data was collected during a 17 hour temperature regulation experiment using a traditional on-off (bang-bang) controller similar to those commonly used for residential heating control. A second order mathematical model was utilized to estimate the net thermal resistances and capacitances using system identification techniques at two different temperature set points. The enclosure system was used to determine if peak power could be reduced by slowly varying loads utilizing a different type of controller. Two different linear control techniques (using K-Factor and PI approaches) and the associated power electronics circuitry were implemented and tuned. Both controller systems successfully leveled the load and reduced the peak power demand.\",\"PeriodicalId\":194092,\"journal\":{\"name\":\"2014 Sixth Annual IEEE Green Technologies Conference\",\"volume\":\"276 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-04-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 Sixth Annual IEEE Green Technologies Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/GREENTECH.2014.15\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 Sixth Annual IEEE Green Technologies Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GREENTECH.2014.15","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An Investigation of Parametric Load Leveling Control Methodologies for Resistive Heaters in Smart Grids
The main goal in this study is to demonstrate that load levelling with demand side management in smart grids can be achieved to reduce peak power consumption while maintaining residential room temperatures at a comfortable level. A prototype enclosure was built and equipped with a heater and thermal measuring equipment. Data was collected during a 17 hour temperature regulation experiment using a traditional on-off (bang-bang) controller similar to those commonly used for residential heating control. A second order mathematical model was utilized to estimate the net thermal resistances and capacitances using system identification techniques at two different temperature set points. The enclosure system was used to determine if peak power could be reduced by slowly varying loads utilizing a different type of controller. Two different linear control techniques (using K-Factor and PI approaches) and the associated power electronics circuitry were implemented and tuned. Both controller systems successfully leveled the load and reduced the peak power demand.