I Katayama, K Nakaura, H Henzan, Z Y Niu, S Kijima, T Kawamura, A Arakawa, T Kohchi, T Katayama, Y Amano
{"title":"[Cosmotech瓷层压修复遮盖效果的比色研究]。","authors":"I Katayama, K Nakaura, H Henzan, Z Y Niu, S Kijima, T Kawamura, A Arakawa, T Kohchi, T Katayama, Y Amano","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The hiding effect on color tone of discolored teeth restored with ceramic laminate veneer crown was examined. Translucent (T1, T2), Enamel (E1, E2, E3), Dentin (DA2, DA3, DB2, DB3), Masking dentin (MDA2, MDA3, MDB2, MDB3) in 13 colors and Modifire (M61, M62, M65, M66, M67, M68, M69, M70, M79) in 7 colors of the ceramic materials (Cosmotech porcelain G C Co., Ltd) were examined in this experiments. The colorimetric examination of the color tone backing with the white or black color was carried out by testing for color difference (delta E*ab), value difference (delta L*), chrom and hue of the samples. The result obtained were as follows; 1. Color difference was higher in order of T2 greater than T1 in Translucent greater than E1 greater than E3 greater than E2 in Enamel greater than DB3 greater than DA2 greater than DA3 greater than DB2 in Dentin greater than MDB3 greater than MDA2 greater than MDB2 greater than MDA3 in Masking dentin, and M69 greater than M79 greater than M70 greater than M68 greater than M66 greater than M61 greater than M62 greater than M67 greater than M65 in Modifire. 2. Value difference was higher in order of T2 greater than T1 in Translucent greater than E1 greater than E3 greater than E2 in Enamel greater than DB3 greater than DA2 greater than DB2 greater than DA3 in Dentin greater than MDA2 greater than MDB3 greater than MDB2 greater than MDA3 in Masking dentin, and M69 greater than M70 greater than M79 greater than M68 greater than M66 greater than M61 greater than M67 greater than M65 greater than M62 in Modifire.(ABSTRACT TRUNCATED AT 250 WORDS)</p>","PeriodicalId":77571,"journal":{"name":"Meikai Daigaku shigaku zasshi = The Journal of Meikai University School of Dentistry","volume":"19 3","pages":"340-8"},"PeriodicalIF":0.0000,"publicationDate":"1990-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Colorimetric studies on hiding effect of Cosmotech porcelain for laminate restoration].\",\"authors\":\"I Katayama, K Nakaura, H Henzan, Z Y Niu, S Kijima, T Kawamura, A Arakawa, T Kohchi, T Katayama, Y Amano\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The hiding effect on color tone of discolored teeth restored with ceramic laminate veneer crown was examined. Translucent (T1, T2), Enamel (E1, E2, E3), Dentin (DA2, DA3, DB2, DB3), Masking dentin (MDA2, MDA3, MDB2, MDB3) in 13 colors and Modifire (M61, M62, M65, M66, M67, M68, M69, M70, M79) in 7 colors of the ceramic materials (Cosmotech porcelain G C Co., Ltd) were examined in this experiments. The colorimetric examination of the color tone backing with the white or black color was carried out by testing for color difference (delta E*ab), value difference (delta L*), chrom and hue of the samples. The result obtained were as follows; 1. Color difference was higher in order of T2 greater than T1 in Translucent greater than E1 greater than E3 greater than E2 in Enamel greater than DB3 greater than DA2 greater than DA3 greater than DB2 in Dentin greater than MDB3 greater than MDA2 greater than MDB2 greater than MDA3 in Masking dentin, and M69 greater than M79 greater than M70 greater than M68 greater than M66 greater than M61 greater than M62 greater than M67 greater than M65 in Modifire. 2. Value difference was higher in order of T2 greater than T1 in Translucent greater than E1 greater than E3 greater than E2 in Enamel greater than DB3 greater than DA2 greater than DB2 greater than DA3 in Dentin greater than MDA2 greater than MDB3 greater than MDB2 greater than MDA3 in Masking dentin, and M69 greater than M70 greater than M79 greater than M68 greater than M66 greater than M61 greater than M67 greater than M65 greater than M62 in Modifire.(ABSTRACT TRUNCATED AT 250 WORDS)</p>\",\"PeriodicalId\":77571,\"journal\":{\"name\":\"Meikai Daigaku shigaku zasshi = The Journal of Meikai University School of Dentistry\",\"volume\":\"19 3\",\"pages\":\"340-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Meikai Daigaku shigaku zasshi = The Journal of Meikai University School of Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Meikai Daigaku shigaku zasshi = The Journal of Meikai University School of Dentistry","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
研究了陶瓷层压贴面冠修复变色牙的隐藏效果。本实验检测了13种颜色的半透明(T1、T2)、珐琅(E1、E2、E3)、牙本质(DA2、DA3、DB2、DB3)、掩蔽牙本质(MDA2、MDA3、MDB2、MDB3)和7种颜色的Modifire (M61、M62、M65、M66、M67、M68、M69、M70、M79)陶瓷材料(Cosmotech porcelain G C Co., Ltd)。通过对样品色差(δ E*ab)、值差(δ L*)、色度和色相的测试,对以白色或黑色为底色的色调进行比色检测。所得结果如下:1. 色差是高等的T2大于T1半透明大于E1大于E3大于E2在搪瓷大于db4大于DA2大于DA3大于DB2在牙质大于MDB3大于MDA2大于MDB2大于MDA3掩蔽牙质,和M69大于M79大于M70大于M68大于M66大于路大于M62大于M67大于M65 Modifire。2。价值的区别是高等的T2大于T1半透明大于E1大于E3大于E2在搪瓷大于db4大于DA2大于DB2大于DA3牙质大于MDA2大于MDB3大于MDB2大于MDA3掩蔽牙质,以及M69大于M70大于M79大于M68大于M66大于路大于M67大于M65大于M62 Modifire。(摘要删节250字)
[Colorimetric studies on hiding effect of Cosmotech porcelain for laminate restoration].
The hiding effect on color tone of discolored teeth restored with ceramic laminate veneer crown was examined. Translucent (T1, T2), Enamel (E1, E2, E3), Dentin (DA2, DA3, DB2, DB3), Masking dentin (MDA2, MDA3, MDB2, MDB3) in 13 colors and Modifire (M61, M62, M65, M66, M67, M68, M69, M70, M79) in 7 colors of the ceramic materials (Cosmotech porcelain G C Co., Ltd) were examined in this experiments. The colorimetric examination of the color tone backing with the white or black color was carried out by testing for color difference (delta E*ab), value difference (delta L*), chrom and hue of the samples. The result obtained were as follows; 1. Color difference was higher in order of T2 greater than T1 in Translucent greater than E1 greater than E3 greater than E2 in Enamel greater than DB3 greater than DA2 greater than DA3 greater than DB2 in Dentin greater than MDB3 greater than MDA2 greater than MDB2 greater than MDA3 in Masking dentin, and M69 greater than M79 greater than M70 greater than M68 greater than M66 greater than M61 greater than M62 greater than M67 greater than M65 in Modifire. 2. Value difference was higher in order of T2 greater than T1 in Translucent greater than E1 greater than E3 greater than E2 in Enamel greater than DB3 greater than DA2 greater than DB2 greater than DA3 in Dentin greater than MDA2 greater than MDB3 greater than MDB2 greater than MDA3 in Masking dentin, and M69 greater than M70 greater than M79 greater than M68 greater than M66 greater than M61 greater than M67 greater than M65 greater than M62 in Modifire.(ABSTRACT TRUNCATED AT 250 WORDS)