一种改进的交流高压测量技术

Sirshendu Saha, S. C. Bera
{"title":"一种改进的交流高压测量技术","authors":"Sirshendu Saha, S. C. Bera","doi":"10.1109/ACES.2014.6808029","DOIUrl":null,"url":null,"abstract":"High a. c. voltage is generally measured by a potential transformer instead of an a.c. volt meter in order to avoid the hazards of high voltage. The conventional potential transformer is specially designed step down transformer where almost accurate voltage between primary and secondary is maintained to obtain output voltage directly proportional to input voltage. But this measurement suffers from ratio error and phase angle error, due to the effects of secondary current, magnetizing current and eddy current. In the present paper attempts have been made to reduce these currents by an improved design technique of the transformer. The technique has been utilized to fabricate a low voltage prototype unit. Its performance characteristics have been experimentally studied in a storage oscilloscope. The experimental results are reported in this paper. From these results a very good linear response with negligible phase angle error has been observed.","PeriodicalId":353124,"journal":{"name":"2014 First International Conference on Automation, Control, Energy and Systems (ACES)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"An improved technique of measurement of high A.C. voltage\",\"authors\":\"Sirshendu Saha, S. C. Bera\",\"doi\":\"10.1109/ACES.2014.6808029\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High a. c. voltage is generally measured by a potential transformer instead of an a.c. volt meter in order to avoid the hazards of high voltage. The conventional potential transformer is specially designed step down transformer where almost accurate voltage between primary and secondary is maintained to obtain output voltage directly proportional to input voltage. But this measurement suffers from ratio error and phase angle error, due to the effects of secondary current, magnetizing current and eddy current. In the present paper attempts have been made to reduce these currents by an improved design technique of the transformer. The technique has been utilized to fabricate a low voltage prototype unit. Its performance characteristics have been experimentally studied in a storage oscilloscope. The experimental results are reported in this paper. From these results a very good linear response with negligible phase angle error has been observed.\",\"PeriodicalId\":353124,\"journal\":{\"name\":\"2014 First International Conference on Automation, Control, Energy and Systems (ACES)\",\"volume\":\"25 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 First International Conference on Automation, Control, Energy and Systems (ACES)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ACES.2014.6808029\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 First International Conference on Automation, Control, Energy and Systems (ACES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ACES.2014.6808029","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

为了避免高电压的危害,通常用电位互感器代替交流电压表来测量高交流电压。传统的电势互感器是专门设计的降压互感器,在初级和次级之间保持几乎精确的电压,使输出电压与输入电压成正比。但由于二次电流、磁化电流和涡流的影响,这种测量存在比误差和相角误差。本文试图通过改进变压器的设计技术来减小这些电流。该技术已用于制造低压样机。在存储示波器上对其性能特性进行了实验研究。本文报道了实验结果。从这些结果中观察到一个非常好的线性响应,相角误差可以忽略不计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An improved technique of measurement of high A.C. voltage
High a. c. voltage is generally measured by a potential transformer instead of an a.c. volt meter in order to avoid the hazards of high voltage. The conventional potential transformer is specially designed step down transformer where almost accurate voltage between primary and secondary is maintained to obtain output voltage directly proportional to input voltage. But this measurement suffers from ratio error and phase angle error, due to the effects of secondary current, magnetizing current and eddy current. In the present paper attempts have been made to reduce these currents by an improved design technique of the transformer. The technique has been utilized to fabricate a low voltage prototype unit. Its performance characteristics have been experimentally studied in a storage oscilloscope. The experimental results are reported in this paper. From these results a very good linear response with negligible phase angle error has been observed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信