UT 805和UT 803万用表对电阻标准测量精度的提高

M. Guzan, Ádám Fehér
{"title":"UT 805和UT 803万用表对电阻标准测量精度的提高","authors":"M. Guzan, Ádám Fehér","doi":"10.1109/EDPE.2019.8883872","DOIUrl":null,"url":null,"abstract":"Article deals with a possibility of more accurate measurement of the resistance standard with a nominal value that is 20 to 60 times smaller than the smallest ohmic range of the multimeter. Compared to direct or indirect one-time measurement, the indirect measurement method using multiple measurements by multiple multimeters is much more accurate. It makes it possible to achieve a relative measurement error in the range of one hundredth to a thousandth of one percent, which significantly exceeds the possibilities of a one-time measurement with a conventional multimeter. This procedure can also be used in practice to measure other resistors, not only resistance standards, without any need of special and expensive measuring apparatus.","PeriodicalId":353978,"journal":{"name":"2019 International Conference on Electrical Drives & Power Electronics (EDPE)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improvement of the Measurement Accuracy of Resistance Standard with UNI-T UT 805 and UT 803 Multimeters\",\"authors\":\"M. Guzan, Ádám Fehér\",\"doi\":\"10.1109/EDPE.2019.8883872\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Article deals with a possibility of more accurate measurement of the resistance standard with a nominal value that is 20 to 60 times smaller than the smallest ohmic range of the multimeter. Compared to direct or indirect one-time measurement, the indirect measurement method using multiple measurements by multiple multimeters is much more accurate. It makes it possible to achieve a relative measurement error in the range of one hundredth to a thousandth of one percent, which significantly exceeds the possibilities of a one-time measurement with a conventional multimeter. This procedure can also be used in practice to measure other resistors, not only resistance standards, without any need of special and expensive measuring apparatus.\",\"PeriodicalId\":353978,\"journal\":{\"name\":\"2019 International Conference on Electrical Drives & Power Electronics (EDPE)\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Conference on Electrical Drives & Power Electronics (EDPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EDPE.2019.8883872\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Electrical Drives & Power Electronics (EDPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EDPE.2019.8883872","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文讨论了用比万用表最小欧姆范围小20 ~ 60倍的标称值对电阻标准进行更精确测量的可能性。与直接或间接的一次性测量相比,使用多个万用表进行多次测量的间接测量方法要精确得多。它使相对测量误差在百分之一到千分之一的范围内成为可能,这大大超过了传统万用表一次性测量的可能性。该方法也可用于实际测量其他电阻,而不仅仅是电阻标准,不需要特殊和昂贵的测量仪器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Improvement of the Measurement Accuracy of Resistance Standard with UNI-T UT 805 and UT 803 Multimeters
Article deals with a possibility of more accurate measurement of the resistance standard with a nominal value that is 20 to 60 times smaller than the smallest ohmic range of the multimeter. Compared to direct or indirect one-time measurement, the indirect measurement method using multiple measurements by multiple multimeters is much more accurate. It makes it possible to achieve a relative measurement error in the range of one hundredth to a thousandth of one percent, which significantly exceeds the possibilities of a one-time measurement with a conventional multimeter. This procedure can also be used in practice to measure other resistors, not only resistance standards, without any need of special and expensive measuring apparatus.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信