{"title":"利用Feldkamp算法重建锥束图像信噪比的决定因素","authors":"X. Wu, R. Johnson, P. Cho","doi":"10.1109/SBEC.1996.493165","DOIUrl":null,"url":null,"abstract":"We quantified the effects of the number of projections used, the cone angle, the projection noise level and detector bit depth on reconstruction signal to noise ratio for conebeam image reconstruction using the Feldkamp algorithm.","PeriodicalId":294120,"journal":{"name":"Proceedings of the 1996 Fifteenth Southern Biomedical Engineering Conference","volume":"110 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-03-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determinants of signal to noise ratio in conebeam image reconstruction using the Feldkamp algorithm\",\"authors\":\"X. Wu, R. Johnson, P. Cho\",\"doi\":\"10.1109/SBEC.1996.493165\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We quantified the effects of the number of projections used, the cone angle, the projection noise level and detector bit depth on reconstruction signal to noise ratio for conebeam image reconstruction using the Feldkamp algorithm.\",\"PeriodicalId\":294120,\"journal\":{\"name\":\"Proceedings of the 1996 Fifteenth Southern Biomedical Engineering Conference\",\"volume\":\"110 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-03-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 1996 Fifteenth Southern Biomedical Engineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SBEC.1996.493165\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1996 Fifteenth Southern Biomedical Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SBEC.1996.493165","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Determinants of signal to noise ratio in conebeam image reconstruction using the Feldkamp algorithm
We quantified the effects of the number of projections used, the cone angle, the projection noise level and detector bit depth on reconstruction signal to noise ratio for conebeam image reconstruction using the Feldkamp algorithm.