两级单相直流-交流电源转换系统消除双线频率纹波的功率解耦控制

A. Amin, W. Choi
{"title":"两级单相直流-交流电源转换系统消除双线频率纹波的功率解耦控制","authors":"A. Amin, W. Choi","doi":"10.23919/icpe2019-ecceasia42246.2019.8797065","DOIUrl":null,"url":null,"abstract":"In two-stage single-phase inverters, inherent double line frequency ripple is present at both input and output of the frontend converter. Generally large electrolytic capacitors are used to eliminate the double line frequency ripple. It is well known that the low frequency ripple shortens the lifespan of the capacitor hence the system reliability may get worse. In order to eliminate the double line frequency ripple additional hardware combined with an energy storage device is required in most of the methods developed so far. In this paper, a novel power-decoupling control method is proposed to eliminate the double line frequency ripple at the front-end converter of the DC /AC power conversion system. The proposed control algorithm is composed of two loops, a ripple compensation loop and an average voltage control loop, and no extra hardware is required. Since the proposed method does not require any information from the phase-locked-loop (PLL) of the inverter it is independent of the inverter control. In order to prove the validity and feasibility of the proposed algorithm a 5kW Dual Active Bridge DC/DC converter and a single-phase inverter are implemented. The effectiveness of the proposed method is verified through the simulation and experimental results.","PeriodicalId":423158,"journal":{"name":"2019 10th International Conference on Power Electronics and ECCE Asia (ICPE 2019 - ECCE Asia)","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Power Decoupling Control of the Two-Stage Single-Phase DC-AC Power Conversion System to Eliminate the Double Line Frequency Ripple\",\"authors\":\"A. Amin, W. Choi\",\"doi\":\"10.23919/icpe2019-ecceasia42246.2019.8797065\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In two-stage single-phase inverters, inherent double line frequency ripple is present at both input and output of the frontend converter. Generally large electrolytic capacitors are used to eliminate the double line frequency ripple. It is well known that the low frequency ripple shortens the lifespan of the capacitor hence the system reliability may get worse. In order to eliminate the double line frequency ripple additional hardware combined with an energy storage device is required in most of the methods developed so far. In this paper, a novel power-decoupling control method is proposed to eliminate the double line frequency ripple at the front-end converter of the DC /AC power conversion system. The proposed control algorithm is composed of two loops, a ripple compensation loop and an average voltage control loop, and no extra hardware is required. Since the proposed method does not require any information from the phase-locked-loop (PLL) of the inverter it is independent of the inverter control. In order to prove the validity and feasibility of the proposed algorithm a 5kW Dual Active Bridge DC/DC converter and a single-phase inverter are implemented. The effectiveness of the proposed method is verified through the simulation and experimental results.\",\"PeriodicalId\":423158,\"journal\":{\"name\":\"2019 10th International Conference on Power Electronics and ECCE Asia (ICPE 2019 - ECCE Asia)\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 10th International Conference on Power Electronics and ECCE Asia (ICPE 2019 - ECCE Asia)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/icpe2019-ecceasia42246.2019.8797065\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 10th International Conference on Power Electronics and ECCE Asia (ICPE 2019 - ECCE Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/icpe2019-ecceasia42246.2019.8797065","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在两级单相逆变器中,在前端变换器的输入和输出端都存在固有的双线频率纹波。一般采用较大的电解电容来消除双线频率纹波。众所周知,低频纹波会缩短电容器的使用寿命,从而降低系统的可靠性。为了消除双线频率纹波,目前开发的大多数方法都需要额外的硬件与储能装置相结合。本文提出了一种新的功率解耦控制方法,以消除直流/交流电源转换系统前端变换器的双线频率纹波。该控制算法由纹波补偿回路和平均电压控制回路两个环组成,不需要额外的硬件。由于该方法不需要逆变器锁相环(PLL)的任何信息,因此它独立于逆变器控制。为了证明所提算法的有效性和可行性,实现了5kW双有源桥式DC/DC变换器和单相逆变器。仿真和实验结果验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Power Decoupling Control of the Two-Stage Single-Phase DC-AC Power Conversion System to Eliminate the Double Line Frequency Ripple
In two-stage single-phase inverters, inherent double line frequency ripple is present at both input and output of the frontend converter. Generally large electrolytic capacitors are used to eliminate the double line frequency ripple. It is well known that the low frequency ripple shortens the lifespan of the capacitor hence the system reliability may get worse. In order to eliminate the double line frequency ripple additional hardware combined with an energy storage device is required in most of the methods developed so far. In this paper, a novel power-decoupling control method is proposed to eliminate the double line frequency ripple at the front-end converter of the DC /AC power conversion system. The proposed control algorithm is composed of two loops, a ripple compensation loop and an average voltage control loop, and no extra hardware is required. Since the proposed method does not require any information from the phase-locked-loop (PLL) of the inverter it is independent of the inverter control. In order to prove the validity and feasibility of the proposed algorithm a 5kW Dual Active Bridge DC/DC converter and a single-phase inverter are implemented. The effectiveness of the proposed method is verified through the simulation and experimental results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信